Evidence map›Paper›PMID 34902345›Full record

ArticleClinica chimica acta; international journal of clinical chemistry2022

Performance verification of five commercial RT-qPCR diagnostic kits for SARS-CoV-2.

Mei Yang, Shuang Cao, Yong Liu, Zhijie Zhang, Rui Zheng, Yuzhong Li, Jie Zhou, Chengguo Zong, Desheng Cao, Xiaosong Qin

Abstract read
In one paragraph

Article in Clinica chimica acta; international journal of clinical chemistry, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.

0numbers the graph read from it
0cells of the map it votes in
19citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

19 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. Article
  13. Article
  14. Observational
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Mei YangDepartment of Laboratory Medicine, Shengjing Hospital of China Medical University, Shenyang, PR China.
Shuang CaoDepartment of Laboratory Medicine, Shengjing Hospital of China Medical University, Shenyang, PR China.
Yong LiuDepartment of Laboratory Medicine, Shengjing Hospital of China Medical University, Shenyang, PR China.
Zhijie ZhangDepartment of Laboratory Medicine, Shengjing Hospital of China Medical University, Shenyang, PR China.
Rui ZhengDepartment of Pulmonary and Critical Care Medicine, Shengjing Hospital of China Medical University, Shenyang, PR China.
Yuzhong LiDepartment of Laboratory Medicine, Second Affiliated Hospital of Dalian Medical University, Dalian, PR China.
Jie ZhouDepartment of Laboratory Medicine, Dalian Muncipal Friendship Hospital, Dalian, PR China.
Chengguo ZongDepartment of Laboratory Medicine, Affiliated Zhongshan Hospital Of Dalian University, Dalian, PR China.
Desheng CaoDepartment of Laboratory Medicine, The Second People's Hospital of Dalian, Dalian, PR China.
Xiaosong QinDepartment of Laboratory Medicine, Shengjing Hospital of China Medical University, Shenyang, PR China. Electronic address: qinxs@sj-hospital.org.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSevere acute respiratory syndrome coronavirus 2 (SARS-CoV-2), which has caused a global pandemic beginning in 2020, can be detected by reverse-transcription polymerase chain reaction (RT-PCR). However, owing to the urgent need for a large number of detection kits, the time spent researching and developing these kits has been shortened during the pandemic, and the kits that are being used commercially have not undergone full and independent evaluation. To ensure the accuracy of SARS-CoV-2 test results, performance verification of commercial Real-Time quantitative PCR (RT-qPCR) kits is required.

methodsThe performance of five commercial RT-qPCR diagnostic kits for SARS-CoV-2 used in China was evaluated using a coronavirus disease 2019 (COVID-19) RNA liquid performance verification reference product-manufactured by Guangzhou Bondson (BDS) Biotechnology Co., Ltd.,Guangzhou, China-that uses droplet digital RT-PCR technology combined with fluorescence quantitative PCR. The five kits of Novel Coronavirus 2019-nCoV nucleic acid detection kit (RT-qPCR method) evaluated were Da An (Da An Gene Co., Ltd. of Sun Yat-sen University), Liferiver (Shanghai ZJ Bio-Tech Co., Ltd.), Kinghawk (Beijing Kinghawk Pharmaceutical Co., Ltd.), eDiagnosis (Wuhan Easy Diagnosis Biomedicine Co., Ltd.), and Maccura (Maccura Biotechnology Co., Ltd.). Performance verification criteria included the coincidence rate, limit of detection (LoD), cross-reactivity, precision, and anti-interference. Finally, through the BDS performance verification reference product kit, clinical samples are used to verify its clinical diagnostic efficacy.

resultsThe coincidence rate was 100% for all kits except for Kinghawk, which was 95%. The LoD for Da An, eDiagnosis and Maccura was 250copies/mL, and it was 1000 copies/ml for Liferiver. Kinghawk was not able to detect its advertised LoD of 500 copies/ml. The cross-reactivity test results were all negative. Moreover, all kits had a coefficient of variation less than 5%; however, Liferiver showed the best precision. Da An, Liferiver, and eDiagnosis showed higher sensitivity to the nucleocapsid (N) gene than they did to the open reading frame (ORF) 1ab genes. Anti-interference results for all five kits were positive. The results of clinical diagnostic efficacy were that the specificity of the four kits was 1.000 (0.877-1.000), the sensitivity of Da An was 1.000 (0.850-1.000), Liferiver was 0.964 (0.798-0.998), Maccura was 0.893 (0.706-0.972), and eDiagnosis was 0.857 (0.664-0.953).

conclusionsAll commercial RT-qPCR diagnostic kits for SARS-CoV-2 passed the BDS performance verification, except for Kinghawk (batch No:20200608113) which failed to detect the LoD of 500 copies/mL. Da An and Liferiver have excellent clinical diagnostic specificity and sensitivity. This study can provide guidance for the selection or optimization of RT-qPCR diagnostic test kits for SARS-CoV-2.

Indexed as

COVID-19SARS-CoV-2ChinaHumansPandemicsReagent Kits, DiagnosticReal-Time Polymerase Chain ReactionRNA, ViralSensitivity and SpecificityReagent Kits, DiagnosticRNA, ViralKitNucleic acid detectionPerformance verificationRT-qPCRSARS-CoV-2

Identifiers

PMID34902345
PMCPMC8662914

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.