ArticleACS omega2021
Uniform Mass Sensitivity Distribution of Elliptically Designed Electrodes Based on a Quartz Crystal Microbalance.
Article in ACS omega, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 6 citations in OpenAlex.
- Quartz Crystal Microbalance-Based Aptasensors for Medical Diagnosis.Micromachines · 2022Review
- Advances in the Mass Sensitivity Distribution of Quartz Crystal Microbalances: A Review.Sensors (Basel, Switzerland) · 2022Review
Corrections and comments
- Erratum issued
Authors and funding
2 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Uniformization of mass sensitivity distribution is conducive to the application of the quartz crystal microbalance (QCM) in some fields. However, the sensitivity of the QCM sensor surface perpendicular to the displacement direction is higher that of the displacement direction in the mass sensitivity distribution of ring and double-ring QCMs, which leads to poor reproducibility of the sensor. Considering the effect of the electrode structure on the mass sensitivity distribution, we found that for ring- and double-ring-type QCMs, when the elliptical single ring and double-ring electrode structures are combined, an approximately uniform mass sensitivity can be obtained in all directions. Therefore, this study proposes the elliptical single-ring and elliptical double-ring electrode structure design. Through theoretical calculations and three-dimensional finite element analysis verification, a systematic investigation is carried out to quantify the effect of the ratio of the minor axis to the major axis of the elliptical electrode on the mass sensitivity distribution in different directions, and the optimal ratio is found to be 0.8. Comparing the mass sensitivity of the new type of electrodes and the original electrodes, the result shows that the mass sensitivity distribution of the elliptical double-ring electrode structure is more uniform. Hence, these specially designed electrodes are conducive to improving the repeatability.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.