Evidence map›Paper›PMID 34901465›Full record

ArticleBMJ open ophthalmology2021

MRI-based 3D retinal shape determination.

Luc van Vught, Denis P Shamonin, Gregorius P M Luyten, Berend C Stoel, Jan-Willem M Beenakker

Open access · goldAbstract read
In one paragraph

Article in BMJ open ophthalmology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.1field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Luc van VughtDepartment of Ophthalmology, Leiden University Medical Center, Leiden, The Netherlands.ORCID 0000-0001-8290-9071
Denis P ShamoninDepartment of Radiology, Division of Image Processing (LKEB), Leiden University Medical Center, Leiden, The Netherlands.ORCID 0000-0002-5614-5351
Gregorius P M LuytenDepartment of Ophthalmology, Leiden University Medical Center, Leiden, The Netherlands.ORCID 0000-0003-3685-3868
Berend C StoelDepartment of Radiology, Division of Image Processing (LKEB), Leiden University Medical Center, Leiden, The Netherlands.ORCID 0000-0002-5975-8559
Jan-Willem M BeenakkerDepartment of Ophthalmology, Leiden University Medical Center, Leiden, The Netherlands.ORCID 0000-0003-0479-5587
Leiden University Medical Center · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo establish a good method to determine the retinal shape from MRI using three-dimensional (3D) ellipsoids as well as evaluate its reproducibility. METHODS AND ANALYSIS: The left eyes of 31 volunteers were imaged using high-resolution ocular MRI. The 3D MR-images were segmented and ellipsoids were fitted to the resulting contours. The dependency of the resulting ellipsoid parameters on the evaluated fraction of the retinal contour was assessed by fitting ellipsoids to 41 different fractions. Furthermore, the reproducibility of the complete procedure was evaluated in four subjects. Finally, a comparison with conventional two-dimensional (2D) methods was made.

resultsThe mean distance between the fitted ellipsoids and the segmented retinal contour was 0.03±0.01 mm (mean±SD) for the central retina and 0.13±0.03 mm for the peripheral retina. For the central retina, the resulting ellipsoid radii were 12.9±0.9, 13.7±1.5 and 12.2±1.2 mm along the horizontal, vertical and central axes. For the peripheral retina, these radii decreased to 11.9±0.6, 11.6±0.4 and 10.4±0.7 mm, which was accompanied by a mean 1.8 mm posterior shift of the ellipsoid centre. The reproducibility of the ellipsoid fitting was 0.3±1.2 mm for the central retina and 0.0±0.1 mm for the peripheral retina. When 2D methods were used to fit the peripheral retina, the fitted radii differed a mean 0.1±0.1 mm from the 3D method.

conclusionAn accurate and reproducible determination of the 3D retinal shape based on MRI is provided together with 2D alternatives, enabling wider use of this method in the field of ophthalmology.

Indexed as

eye (Globe)imagingoptics and refractionretina

Identifiers

PMID34901465
PMCPMC8611437
OpenAlexW3217260797

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.