Evidence map›Paper›PMID 34896309›Full record

ArticleExperimental eye research2022

An ex vivo model of human corneal rim perfusion organ culture.

Michael Peng, Tyler J Margetts, Chenna Kesavulu Sugali, Naga Pradeep Rayana, Jiannong Dai, Tasneem P Sharma, Vijay Krishna Raghunathan, Weiming Mao

Open access · greenAbstract read
In one paragraph

Article in Experimental eye research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
2.1field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Article
  3. Human Corneal Rim Perfusion Culture.Methods in molecular biology (Clifton, N.J.) · 2025
    Article
  4. Article
  5. GSK3β Inhibitors Inhibit TGFβ Signaling in the Human Trabecular Meshwork.Investigative ophthalmology & visual science · 2024
    Article
  6. Article
  7. Progress in the application of 3D printing technology in ophthalmology.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2023
    Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Michael PengEugene and Marilyn Glick Eye Institute, Department of Ophthalmology, Indiana University School of Medicine, USA.
Tyler J MargettsEugene and Marilyn Glick Eye Institute, Department of Ophthalmology, Indiana University School of Medicine, USA.
Chenna Kesavulu SugaliEugene and Marilyn Glick Eye Institute, Department of Ophthalmology, Indiana University School of Medicine, USA.
Naga Pradeep RayanaEugene and Marilyn Glick Eye Institute, Department of Ophthalmology, Indiana University School of Medicine, USA.
Jiannong DaiEugene and Marilyn Glick Eye Institute, Department of Ophthalmology, Indiana University School of Medicine, USA.
Tasneem P SharmaEugene and Marilyn Glick Eye Institute, Department of Ophthalmology, Indiana University School of Medicine, USA; Department of Pharmacology and Toxicology, Indiana University School of Medicine, USA.
Vijay Krishna RaghunathanThe Ocular Surface Institute, Department of Basic Sciences, College of Optometry, University of Houston, USA; Department of Biomedical Engineering, Cullen College of Engineering, University of Houston, USA.
Weiming MaoEugene and Marilyn Glick Eye Institute, Department of Ophthalmology, Indiana University School of Medicine, USA; Department of Pharmacology and Toxicology, Indiana University School of Medicine, USA; Department of Biochemistry and Molecular Biology, Indiana University School of Medicine, USA. Electronic address: weimmao@iu.edu.
Indiana University School of MedicineOcular Surface Center · US

Funding

Quality Assurance and Quality Control Project Management: Improving Submissions and Study Conduct in the Human Subjects Research Prior Approval ProcessUL1TR002529 · NCATS · INDIANA UNIVERSITY INDIANAPOLIS · PI MOE, SHARON M, WIEHE, SARAH ELIZABETH · 2018 to 2022
$27.2M
The role of Wnt signaling in treating glucocorticoid-induced glaucomaR01EY031700 · NEI · INDIANA UNIVERSITY INDIANAPOLIS · PI MAO, WEIMING · 2021 to 2025
$2.5M
Cross-talk between TGF-beta and Wnt pathways in the trabecular meshworkR01EY026962 · NEI · UNIVERSITY OF NORTH TEXAS HLTH SCI CTR · PI MAO, WEIMING · 2017 to 2021
$1.9M
Mechanotransduction in Aqueous Outflow Regulation and Open Angle GlaucomaR01EY026048 · NEI · OREGON HEALTH & SCIENCE UNIVERSITY · PI ACOTT, TED S, RAGHUNATHAN, VIJAYKRISHNA · 2018 to 2021
$1.5M
Short-Term Training in Ophthalmology Research for Medical StudentsT35EY031282 · NEI · INDIANA UNIVERSITY INDIANAPOLIS · PI Ashay D Bhatwadekar, John Thompson Lind · 2020 to 2026
$354k
NCATS NIH HHS UL1 TR002529NEI NIH HHS R01 EY026048NEI NIH HHS R01 EY026962NEI NIH HHS R01 EY031700NEI NIH HHS T35 EY031282
6 · The paper itself

Abstract

The human anterior segment perfusion culture model is a valuable tool for studying the trabecular meshwork (TM) and aqueous humor outflow in glaucoma. The traditional model relies on whole eye globes resulting in high cost and limited availability. Here, we developed a glue-based method which enabled us to use human corneal rims for perfusion culture experiments. Human corneal rim perfusion culture plates were 3D printed. Human corneal rims containing intact TM were attached and sealed to the plate using low viscosity and high viscosity glues, respectively. The human corneal rims were perfused using the constant flow mode, and the pressure changes were recorded using a computerized system. Outflow facility, TM stiffness, and TM morphology were evaluated. When perfused at rates from 1.2 to 3.6 μl/min, the outflow facility was 0.359 ± 0.216 μl/min/mmHg among 10 human corneal rims. The stiffness of the TM in naïve human corneal rim was similar to that of perfusion cultured human corneal rim. Also, the stiffness of TM of corneal rims perfused with dexamethasone was significantly higher than the control. Human corneal rims with glue contamination in the TM could be differentiated by high baseline intraocular pressure as well as high TM stiffness. Histology studies showed that the TM tissues perfused with plain medium appeared normal. We believed that our glued-based method is a useful tool and low-cost alternative to the traditional anterior segment perfusion culture model.

Indexed as

Models, BiologicalOrgan Culture TechniquesAqueous HumorCorneaElastic ModulusHumansIntraocular PressureMicroscopy, Atomic ForceTissue AdhesivesTissue DonorsTrabecular MeshworkTissue AdhesivesAnterior segment perfusion cultureAqueous humor outflowCorneal rimStiffnessTrabecular meshwork

Identifiers

PMID34896309
PMCPMC8792355
OpenAlexW4200593589

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.