Evidence map›Paper›PMID 34893931›Full record

ArticleJournal of medical systems2021

Diabetic Macular Edema Screened by Handheld Smartphone-based Retinal Camera and Artificial Intelligence.

Fernando Korn Malerbi, Giovana Mendes, Nathan Barboza, Paulo Henrique Morales, Roseanne Montargil, Rafael Ernane Andrade

Open access · bronzeAbstract read
In one paragraph

Article in Journal of medical systems, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
3.3field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 30 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 1 country.

Fernando Korn MalerbiDepartment of Ophthalmology and Visual Sciences, Federal University of São Paulo, São Paulo-SP, Brazil. fernandokmalerbi@gmail.com.ORCID http://orcid.org/0000-0002-6523-5172
Giovana MendesHospital de Olhos Beira Rio, Itabuna, BA, Brazil.
Nathan BarbozaFaculdade de Medicina Santo Agostinho, Itabuna, BA, Brazil.
Paulo Henrique MoralesDepartment of Ophthalmology and Visual Sciences, Federal University of São Paulo, São Paulo-SP, Brazil.
Roseanne MontargilUniversidade Estadual de Santa Cruz, Ilheus, BA, Brazil.
Rafael Ernane AndradeHospital de Olhos Beira Rio, Itabuna, BA, Brazil.
Instituto de Olhos de Goiânia · BRInstituto da Visão · BRUniversidade Estadual de Santa Cruz · BRUniversidade Federal de São Paulo · BR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Our aim was to assess the tomographic presence of diabetic macular edema in type 2 diabetes patients screened for diabetic retinopathy with color fundus photographs and an artificial intelligence algorithm. Color fundus photographs obtained with a low-cost smartphone-based handheld retinal camera were analyzed by the algorithm; patients with suspected macular lesions underwent ocular coherence tomography. A total of 366 patients were screened; diabetic macular edema was suspected in 34 and confirmed in 29 individuals, with average age 60.5 ± 10.9 years and glycated hemoglobin 9.8 ± 2.4%; use of insulin, statins, and aspirin were reported in 44.8%, 37.9%, and 34.5% of individuals, respectively; systemic blood hypertension, dyslipidemia, abdominal obesity, chronic kidney disease, and risk for diabetic foot ulcers were present in 100%, 58.6%, 62.1%, 48.3%, and 27.5% of individuals, respectively. Proliferative diabetic retinopathy was present in 31% of patients with macular edema; severity level was associated with albuminuria (p = 0.028). Eyes with macular edema had average central macular thickness 329.89 ± 80.98 m[Formula: see text]; intraretinal cysts, sub retinal fluid, hyper-reflective foci, epiretinal membrane, and vitreomacular traction were found in 87.2%, 6.4%, 85.1%, 10.6%, and 6.4% of eyes, respectively. Diabetic retinopathy screening overwhelms health systems and is typically based on color fundus photographs, with high false-positive rates for the detection of diabetic macular edema. The present, semi-automated strategy comprising artificial intelligence algorithms integrated with smartphone-based retinal cameras could improve screening in low-resource settings with limited availability of ocular coherence tomography, allowing increased access rates and ultimately contributing to tackle preventable blindness.

Indexed as

Diabetes Mellitus, Type 2Diabetic RetinopathyMacular EdemaAgedArtificial IntelligenceHumansMiddle AgedSmartphoneArtificial intelligenceDiabetic retinopathyMobile healthPublic health

Identifiers

PMID34893931
PMCPMC8664675
OpenAlexW4200430049

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.