ArticleScientific reports2021
A bench-to-bedside study about trigger asynchronies induced by the introduction of external gas into the non-invasive mechanical ventilation circuit.
Article in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Ventilators, Settings, Autotitration Algorithms.Journal of clinical medicine · 2023Review
- What Circuits, Masks and Filters Should Be Used in Home Non-Invasive Mechanical Ventilation.Journal of clinical medicine · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Treatments that require the introduction of external gas into the non-invasive ventilation (NIV) circuit, such as aerosol and oxygen therapy, may influence the performance of the ventilator trigger system. The aim of the study was to determine the presence and type of asynchronies induced by external gas in the NIV circuit in a bench model and in a group of patients undergoing chronic NIV. Bench study: Four ventilators (one with two different trigger design types) and three gas sources (continuous flow at 4 and 9 l/min and pulsatile flow at 9 l/min) were selected in an active simulator model. The sensitivity of the trigger, the gas introduction position, the ventilatory pattern and the level of effort were also modified. The same ventilators and gas conditions were used in patients undergoing chronic NIV. Bench: the introduction of external gas caused asynchronies in 35.9% of cases (autotriggering 73%, ineffective effort 27%). Significant differences (p < 0.01) were detected according to the ventilator model and the gas source. In seven patients, the introduction of external gas induced asynchrony in 20.4% of situations (77% autotriggering). As in the bench study, there were differences in the occurrence of asynchronies depending on the ventilator model and gas source used. The introduction of external gas produces alterations in the ventilator trigger. These alterations are variable, and depend on the ventilator design and gas source. This phenomenon makes it advisable to monitor the patient at the start of treatment.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials