Is cement-augmented sacroiliac screw fixation with partially threaded screws superior to that with fully threaded screws concerning compression and pull-out force in fragility fractures of the sacrum? - a biomechanical analysis.

Juliana Hack, Maiwand Safi, Martin Bäumlein, Julia Lenz, Christopher Bliemel, Steffen Ruchholtz, Ludwig Oberkircher

Open access · goldAbstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.8field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Influencing factors for fragility fractures of the pelvis on length of stay and complication rate.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2025
    Article
  2. The ideal site of cement application in cement augmented sacroiliac screw fixation: the biomechanical perspective.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Juliana HackCenter for Orthopaedics and Trauma Surgery, University Hospital Giessen and Marburg GmbH, Baldingerstrasse, 35043, Marburg, Germany. hackj@med.uni-marburg.de.
Maiwand SafiCenter for Orthopaedics and Trauma Surgery, University Hospital Giessen and Marburg GmbH, Baldingerstrasse, 35043, Marburg, Germany.
Martin BäumleinCenter for Orthopaedics and Trauma Surgery, University Hospital Giessen and Marburg GmbH, Baldingerstrasse, 35043, Marburg, Germany.
Julia LenzCenter for Orthopaedics and Trauma Surgery, University Hospital Giessen and Marburg GmbH, Baldingerstrasse, 35043, Marburg, Germany.
Christopher BliemelCenter for Orthopaedics and Trauma Surgery, University Hospital Giessen and Marburg GmbH, Baldingerstrasse, 35043, Marburg, Germany.
Steffen RuchholtzCenter for Orthopaedics and Trauma Surgery, University Hospital Giessen and Marburg GmbH, Baldingerstrasse, 35043, Marburg, Germany.
Ludwig OberkircherCenter for Orthopaedics and Trauma Surgery, University Hospital Giessen and Marburg GmbH, Baldingerstrasse, 35043, Marburg, Germany.
Universitätsklinikum Gießen und Marburg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundProviding a stable osteosynthesis in fragility fractures of the pelvis can be challenging. Cement augmentation increases screw fixation in osteoporotic bone. Generating interfragmentary compression by using a lag screw also improves the stability. However, it is not known if interfragmentary compression can be achieved in osteoporotic sacral bone by cement augmentation of lag screws. The purpose of this study was to compare cement-augmented sacroiliac screw osteosynthesis using partially versus fully threaded screws in osteoporotic hemipelvises concerning compression of fracture gap and pull-out force.

methodsNine fresh-frozen human cadaveric pelvises with osteoporosis were used. In all specimens, one side was treated with an augmented fully threaded screw (group A), and the other side with an augmented partially threaded screw (group B) after generating a vertical osteotomy on both sides of each sacrum. Afterwards, first a compression test with fracture gap measurement after tightening of the screws was performed, followed by an axial pull-out test measuring the maximum pull-out force of the screws.

resultsThe fracture gap was significantly wider in group A (mean: 1.90 mm; SD: 1.64) than in group B (mean: 0.91 mm; SD: 1.03; p = 0.028). Pull-out force was higher in group A (mean: 1696 N; SD: 1452) than in group B (mean: 1616 N; SD: 824), but this difference was not statistically significant (p = 0.767).

conclusionsCement augmentation of partially threaded screws in sacroiliac screw fixation allows narrowing of the fracture gap even in osteoporotic bone, while resistance against pull-out force is not significantly lower in partially threaded screws compared to fully threaded screws.

Indexed as

Bone ScrewsSacrumBiomechanical PhenomenaBone CementsHumansPelvisBone CementsCement augmentationFragility fracture of the pelvisFully threaded screwOsteoporosisPartially threaded screw

Identifiers

PMID34893059
PMCPMC8665623
OpenAlexW4200159407

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.