SynthesisThe Cochrane database of systematic reviews2021
Humidification of indoor air for preventing or reducing dryness symptoms or upper respiratory infections in educational settings and at the workplace.
Synthesis in The Cochrane database of systematic reviews, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 2 syntheses or guidelines pooled it, 23 citations in OpenAlex.
- Prevalence of dry eye and Meibomian gland dysfunction in Central and South America: a systematic review and meta-analysis.BMC ophthalmology · 2024Pooled it
- Humidification of indoor air for preventing or reducing dryness symptoms or upper respiratory infections in educational settings and at the workplace.The Cochrane database of systematic reviews · 2021Pooled it
- Trial
- Interaction effects of environmental factors with white blood cell profiles on mycobacterial pulmonary diseases: a case-control study.BMC infectious diseases · 2025Article
- Pregnancy Rhinitis: Pathophysiological Mechanisms, Diagnostic Challenges, and Management Strategies-A Narrative Review.Life (Basel, Switzerland) · 2025Review
- Systematic Evaluation of How Indicators of Inequity and Disadvantage Are Measured and Reported in Population Health Evidence Syntheses.International journal of environmental research and public health · 2025Review
- Association between sleep and meteorology in late-onset depression patients.BMC psychiatry · 2025Article
- Short-term exposure to relative humidity and lung health in early adolescents.Environmental epidemiology (Philadelphia, Pa.) · 2025Article
- Reduction of acute respiratory infections in day-care by non-pharmaceutical interventions: a narrative review.Frontiers in public health · 2024Review
- Environmental and Occupational Triggers of Dry Eye Symptoms in the Ahsa Region of Saudi Arabia: A Cross-Sectional Study.Clinical ophthalmology (Auckland, N.Z.) · 2024Article
- Interventions for Dry Eye: An Overview of Systematic Reviews.JAMA ophthalmology · 2024Article
- Relative Humidity and Its Impact on the Immune System and Infections.International journal of molecular sciences · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundIndoor exposure to dry air during heating periods has been associated with dryness and irritation symptoms of the upper respiratory airways and the skin. The irritated or damaged mucous membrane poses an important entry port for pathogens causing respiratory infections.
objectivesTo determine the effectiveness of interventions that increase indoor air humidity in order to reduce or prevent dryness symptoms of the eyes, the skin and the upper respiratory tract (URT) or URT infections, at work and in educational settings. SEARCH
methodsThe last search for all databases was done in December 2020. We searched Ovid MEDLINE, Embase, CENTRAL (Cochrane Library), PsycINFO, Web of Science, Scopus and in the field of occupational safety and health: NIOSHTIC-2, HSELINE, CISDOC and the In-house database of the Division of Occupational and Environmental Medicine, University of Zurich. We also contacted experts, screened reference lists of included trials, relevant reviews and consulted the WHO International Clinical Trials Registry Platform (ICTRP). SELECTION CRITERIA: We included controlled studies with a parallel group or cross-over design, quasi-randomised studies, controlled before-and-after and interrupted time-series studies on the effects of indoor air humidification in reducing or preventing dryness symptoms and upper respiratory tract infections as primary outcomes at workplace and in the educational setting. As secondary outcomes we considered perceived air quality, other adverse events, sick leave, task performance, productivity and attendance and costs of the intervention. DATA COLLECTION AND ANALYSIS: Two review authors independently screened titles, abstracts and full texts for eligibility, extracted data and assessed the risks of bias of included studies. We synthesised the evidence for the primary outcomes 'dry eye', 'dry nose', 'dry skin', for the secondary outcome 'absenteeism', as well as for 'perception of stuffiness' as the harm-related measure. We assessed the certainty of evidence using the GRADE system. MAIN
resultsWe included 13 studies with at least 4551 participants, and extracted the data of 12 studies with at least 4447 participants. Seven studies targeted the occupational setting, with three studies comprising office workers and four hospital staff. Three of them were clustered cross-over studies with 846 participants (one cRCT), one parallel-group controlled trial (2395 participants) and three controlled before-and-after studies with 181 participants. Five studies, all CTs, with at least 1025 participants, addressing the educational setting, were reported between 1963 and 1975, and in 2018. In total, at least 3933 (88%) participants were included in the data analyses. Due to the lack of information, the results of the risk of bias assessment remained mainly unclear and the assessable risks of bias of included studies were considered as predominantly high. Primary outcomes in occupational setting: We found that indoor air humidification at the workplace may have little to no effect on dryness symptoms of the eye and nose (URT). The only cRCT showed a significant decrease in dry eye symptoms among working adults (odds ratio (OR) 0.54, 95% confidence interval (CI) 0.37 to 0.79) with a low certainty of the evidence. The only cluster non-randomised cross-over study showed a non-significant positive effect of humidification on dryness nose symptoms (OR 0.87, 95% CI 0.53 to 1.42) with a low certainty of evidence. We found that indoor air humidification at the workplace may have little and non-significant effect on dryness skin symptoms. The pooled results of two cluster non-RCTs showed a non-significant alleviation of skin dryness following indoor air humidification (OR 0.66, 95% CI 0.33 to 1.32) with a low certainty of evidence. Similarly, the pooled results of two before-after studies yielded no statistically significant result (OR 0.69, 95% CI 0.33 to 1.47) with very low certainty of evidence No studies reported on the outcome of upper respiratory tract infections. No studies conducted in educational settings investigated our primary outcomes. Secondary outcomes in occupational setting: Perceived stuffiness of the air was increased during the humidification in the two cross-over studies (OR 2.18, 95% CI 1.47 to 3.23); (OR 1.70, 95% CI 1.10 to 2.61) with low certainty of evidence. Secondary outcomes in educational setting: Based on different measures and settings of absenteeism, four of the six controlled studies found a reduction in absenteeism following indoor air humidification (OR 0.54, 95% CI 0.45 to 0.65; OR 0.38, 95% CI 0.15 to 0.96; proportion 4.63% versus 5.08%). AUTHORS'
conclusionsIndoor air humidification at the workplace may have little to no effect on dryness symptoms of the eyes, the skin and the URT. Studies investigating illness-related absenteeism from work or school could only be summarised narratively, due to different outcome measures assessed. The evidence suggests that increasing humidification may reduce the absenteeism, but the evidence is very uncertain. Future RCTs involving larger sample sizes, assessing dryness symptoms more technically or rigorously defining absenteeism and controlling for potential confounders are therefore needed to determine whether increasing indoor air humidity can reduce or prevent dryness symptoms of the eyes, the skin, the URT or URT infections at work and in educational settings over time.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials