ArticleQuantitative imaging in medicine and surgery2021
Prior image-guided cone-beam computed tomography augmentation from under-sampled projections using a convolutional neural network.
Article in Quantitative imaging in medicine and surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Low-dose CBCT image reconstruction: a review.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2026Review
- [Advances in low-dose cone-beam computed tomography image reconstruction methods based on deep learning].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2025Review
- Artificial intelligence in four-dimensional imaging for motion management in radiation therapy.Artificial intelligence review · 2025Article
- Non-coplanar CBCT image reconstruction using a generative adversarial network for non-coplanar radiotherapy.Journal of applied clinical medical physics · 2024Article
- 3DPhysics in medicine and biology · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
backgroundAcquiring sparse-view cone-beam computed tomography (CBCT) is an effective way to reduce the imaging dose. However, images reconstructed by the conventional filtered back-projection method suffer from severe streak artifacts due to the projection under-sampling. Existing deep learning models have demonstrated feasibilities in restoring volumetric structures from the highly under-sampled images. However, because of the inter-patient variabilities, they failed to restore the patient-specific details with the common restoring pattern learned from the group data. Although the patient-specific models have been developed by training models using the intra-patient data and have shown effectiveness in restoring the patient-specific details, the models have to be retrained to be exclusive for each patient. It is highly desirable to develop a generalized model that can utilize the patient-specific information for the under-sampled image augmentation.
methodsIn this study, we proposed a merging-encoder convolutional neural network (MeCNN) to realize the prior image-guided under-sampled CBCT augmentation. Instead of learning the patient-specific structures, the proposed model learns a generalized pattern of utilizing the patient-specific information in the prior images to facilitate the under-sampled image enhancement. Specifically, the MeCNN consists of a merging-encoder and a decoder. The merging-encoder extracts image features from both the prior CT images and the under-sampled CBCT images, and merges the features at multi-scale levels via deep convolutions. The merged features are then connected to the decoders via shortcuts to yield high-quality CBCT images. The proposed model was tested on both the simulated CBCTs and the clinical CBCTs. The predicted CBCT images were evaluated qualitatively and quantitatively in terms of image quality and tumor localization accuracy. Mann-Whitney U test was conducted for the statistical analysis. P<0.05 was considered statistically significant.
resultsThe proposed model yields CT-like high-quality CBCT images from only 36 half-fan projections. Compared to other methods, CBCT images augmented by the proposed model have significantly lower intensity errors, significantly higher peak signal-to-noise ratio, and significantly higher structural similarity with respect to the ground truth images. Besides, the proposed method significantly reduced the 3D distance of the CBCT-based tumor localization errors. In addition, the CBCT augmentation is nearly real-time.
conclusionsWith the prior-image guidance, the proposed method is effective in reconstructing high-quality CBCT images from the highly under-sampled projections, considerably reducing the imaging dose and improving the clinical utility of the CBCT.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.