Evidence map›Paper›PMID 34885400›Full record

ArticleMaterials (Basel, Switzerland)2021

Analysis of the Risk of Wear on Cemented and Uncemented Polyethylene Liners According to Different Variables in Hip Arthroplasty.

Basilio De la Torre, Loreto Barrios, Juan De la Torre-Mosquera, Julia Bujan, Miguel A Ortega, Carlos González-Bravo

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Basilio De la TorreDepartment of Surgery, Medical and Social Sciences, Faculty of Medicine and Health Sciences, Ramón y Cajal Institute of Sanitary Research (IRYCIS), University of Alcala, Alcala de Henares, 28871 Madrid, Spain.
Loreto BarriosA + I Architecture and Engineering Ltd., 28034 Madrid, Spain.
Juan De la Torre-MosqueraDepartment of Medicine and Medical Specialities, Faculty of Medicine and Health Sciences, Ramón y Cajal Institute of Sanitary Research (IRYCIS), University of Alcala, Alcala de Henares, 28871 Madrid, Spain.ORCID 0000-0003-3592-3940
Julia BujanDepartment of Medicine and Medical Specialities, Faculty of Medicine and Health Sciences, Ramón y Cajal Institute of Sanitary Research (IRYCIS), University of Alcala, Alcala de Henares, 28871 Madrid, Spain.ORCID 0000-0003-2419-2476
Miguel A OrtegaDepartment of Medicine and Medical Specialities, Faculty of Medicine and Health Sciences, Ramón y Cajal Institute of Sanitary Research (IRYCIS), University of Alcala, Alcala de Henares, 28871 Madrid, Spain.ORCID 0000-0003-2588-1708
Carlos González-BravoDepartment of Medicine and Medical Specialities, Faculty of Medicine and Health Sciences, Ramón y Cajal Institute of Sanitary Research (IRYCIS), University of Alcala, Alcala de Henares, 28871 Madrid, Spain.ORCID 0000-0001-5491-5693

Funding

METHADONE TREATMENT: A STUDY OF A COUNTY POLICY CHANGER01DA003804 · NIDA · SCIENTIFIC ANALYSIS CORPORATION · PI ROSENBAUM, MARSHA · 1985 to 1989
–
Comunidad de Madrid B2017/BMD-3804 MITIC-CM
6 · The paper itself

Abstract

Wear debris in total hip arthroplasty is one of the main causes of loosening and failure, and the optimal acetabular fixation for primary total hip arthroplasty is still controversial because there is no significant difference between cemented and uncemented types for long-term clinical and functional outcome. To assess and predict, from a theoretical viewpoint, the risk of wear with two types of polyethylene liners, cemented and uncemented, a simulation using the finite element (FE) method was carried out. The risk of wear was analyzed according to different variables: the polyethylene acetabular component's position with respect to the center of rotation of the hip; the thickness of the polyethylene insert; the material of the femoral head; and the relationship of the cervical-diaphyseal morphology of the proximal end of the femur to the restoration of the femoral offset. In all 72 simulations studied, a difference was observed in favour of a cemented solution with respect to the risk of wear. With regard to the other variables, the acetabular fixation, the thickness of the polyethylene, and the acetabular component positioning were statistically significant. The highest values for the risk of wear corresponded to a smaller thickness (5.3 mm), and super-lateral positioning at 25 mm reached the highest value of the von Mises stress. According to our results, for the reconstruction of the acetabular side, a cemented insert with a thickness of at least 5 mm should be used at the center of rotation.

Indexed as

cemented–uncemented polyethylene linercenter of rotationfinite element analysis modelrisk of wearthickness of polyethylene