Evidence map›Paper›PMID 34884134›Full record

ArticleSensors (Basel, Switzerland)2021

Evaluation of Viscosity Dependence of the Critical Meniscus Height with Optical Fiber Sensors.

Leonardo Binetti, Fraser Simpson, Lourdes S M Alwis

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Leonardo BinettiSchool of Engineering and the Built Environment, Edinburgh Napier University, Edinburgh EH10 5DT, UK.ORCID 0000-0002-2492-8722
Fraser SimpsonSchool of Engineering and the Built Environment, Edinburgh Napier University, Edinburgh EH10 5DT, UK.
Lourdes S M AlwisSchool of Engineering and the Built Environment, Edinburgh Napier University, Edinburgh EH10 5DT, UK.ORCID 0000-0001-8488-2992

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Conventional means of data extraction using optical fiber interrogators are not adequate for fast-paced detection of a target parameter. In this instance, the relationship between the critical meniscus heights (CMH) of several liquids to the extraction speed of a rod submerged in them, have been analyzed. A limitation of a previous interrogator used for the purpose had been light absorption by the liquid due to the used bandwidth of the readily-available light source, i.e., C-band. The newly proposed technique addresses this limitation by utilizing a broadband light source instead, with a Si-photodetector and an Arduino. In addition, the Arduino is capable of extracting data at a relatively faster rate with respect to the conventional optical interrogator. The use of a different operational wavelength (850 nm instead of 1550 nm) increased the r

Indexed as

critical meniscus heightdynamic viscosityspectroscopysurface tension

Identifiers

PMID34884134
PMCPMC8662447

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.