Evidence map›Paper›PMID 34884062›Full record

ArticleSensors (Basel, Switzerland)2021

Online Frequency Response Analysis of Electric Machinery through an Active Coupling System Based on Power Electronics.

Wilson Cesar Sant'Ana, Germano Lambert-Torres, Erik Leandro Bonaldi, Bruno Reno Gama, Tiago Goncalves Zacarias, Isac Antonio Dos Santos Areias, Daniel de Almeida Arantes, Frederico de Oliveira Assuncao, Mateus Mendes Campos, Fabio Monteiro Steiner

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Wilson Cesar Sant'AnaGnarus Institute, Itajuba 37500-052, MG, Brazil.ORCID 0000-0003-2335-4584
Germano Lambert-TorresGnarus Institute, Itajuba 37500-052, MG, Brazil.ORCID 0000-0003-3789-4696
Erik Leandro BonaldiGnarus Institute, Itajuba 37500-052, MG, Brazil.
Bruno Reno GamaPro-Reitoria de Pesquisa e Pos-Graduacao (PRPPG), Itajuba Federal University, Itajuba 37500-903, MG, Brazil.ORCID 0000-0002-5366-8341
Tiago Goncalves ZacariasGnarus Institute, Itajuba 37500-052, MG, Brazil.
Isac Antonio Dos Santos AreiasPro-Reitoria de Pesquisa e Pos-Graduacao (PRPPG), Itajuba Federal University, Itajuba 37500-903, MG, Brazil.
Daniel de Almeida ArantesPro-Reitoria de Pesquisa e Pos-Graduacao (PRPPG), Itajuba Federal University, Itajuba 37500-903, MG, Brazil.
Frederico de Oliveira AssuncaoGnarus Institute, Itajuba 37500-052, MG, Brazil.
Mateus Mendes CamposGnarus Institute, Itajuba 37500-052, MG, Brazil.ORCID 0000-0002-8654-1048
Fabio Monteiro SteinerEDF Norte Fluminense, Macae 27910-970, RJ, Brazil.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper presents an innovative concept for the online application of Frequency Response Analysis (FRA). FRA is a well known technique that is applied to detect damage in electric machinery. As an offline technique, the machine under testing has to be removed from service-which may cause loss of production. Experimental adaptations of FRA to online operation are usually based on the use of passive high pass coupling-which, ideally, should provide attenuation to the grid voltage, and at the same time, allow the high frequency FRA signals to be injected at the machine. In practice, however, the passive coupling results in a trade-off between the required attenuation and the useful area obtained at the FRA spectra. This paper proposes the use of an active coupling system, based on power electronics, in order to cancel the grid voltage at the terminals of FRA equipment and allow its safe connection to an energized machine. The paper presents the basic concepts of FRA and the issue of online measurements. It also presents basic concepts about power electronics converters and the operating principles of the Modular Multilevel Converter, which enables the generation of an output voltage with low THD, which is important for tracking the grid voltage with minimum error.

Indexed as

ElectricityElectric Power SuppliesElectronicsEquipment Designcondition based monitoringelectric machineryfailure diagnosisfrequency response analysismodular multilevel converterspower electronicspredictive maintenance

Identifiers

PMID34884062
PMCPMC8659803

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.