Evidence map›Paper›PMID 34883959›Full record

ArticleSensors (Basel, Switzerland)2021

Effects of Different Parameter Settings for 3D Data Smoothing and Mesh Simplification on Near Real-Time 3D Reconstruction of High Resolution Bioceramic Bone Void Filling Medical Images.

Daniel Jie Yuan Chin, Ahmad Sufril Azlan Mohamed, Khairul Anuar Shariff, Mohd Nadhir Ab Wahab, Kunio Ishikawa

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Daniel Jie Yuan ChinSchool of Computer Sciences, Universiti Sains Malaysia, Gelugor 11800, Penang, Malaysia.ORCID 0000-0002-2266-9501
Ahmad Sufril Azlan MohamedSchool of Computer Sciences, Universiti Sains Malaysia, Gelugor 11800, Penang, Malaysia.ORCID 0000-0002-2838-0872
Khairul Anuar ShariffSchool of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, Engineering Campus, Nibong Tebal 14300, Penang, Malaysia.ORCID 0000-0003-3331-2505
Mohd Nadhir Ab WahabSchool of Computer Sciences, Universiti Sains Malaysia, Gelugor 11800, Penang, Malaysia.ORCID 0000-0002-3549-6443
Kunio IshikawaDepartment of Biomaterials, Faculty of Dental Science, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan.

Funding

Ministry of Higher Education Malaysia for Fundamental Research Grant Scheme FRGS/1/2020/STG07/USM/02/12
6 · The paper itself

Abstract

Three-dimensional reconstruction plays a vital role in assisting doctors and surgeons in diagnosing the healing progress of bone defects. Common three-dimensional reconstruction methods include surface and volume rendering. As the focus is on the shape of the bone, this study omits the volume rendering methods. Many improvements have been made to surface rendering methods like Marching Cubes and Marching Tetrahedra, but not many on working towards real-time or near real-time surface rendering for large medical images and studying the effects of different parameter settings for the improvements. Hence, this study attempts near real-time surface rendering for large medical images. Different parameter values are experimented on to study their effect on reconstruction accuracy, reconstruction and rendering time, and the number of vertices and faces. The proposed improvement involving three-dimensional data smoothing with convolution kernel Gaussian size 5 and mesh simplification reduction factor of 0.1 is the best parameter value combination for achieving a good balance between high reconstruction accuracy, low total execution time, and a low number of vertices and faces. It has successfully increased reconstruction accuracy by 0.0235%, decreased the total execution time by 69.81%, and decreased the number of vertices and faces by 86.57% and 86.61%, respectively.

Indexed as

Imaging, Three-DimensionalSurgical MeshAlgorithmsNormal DistributionProstheses and Implants3D data smoothing3D reconstructionhigh resolution micro-CT imagesmesh simplification

Identifiers

PMID34883959
PMCPMC8659505

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.