Evidence map›Paper›PMID 34883791›Full record

ArticleSensors (Basel, Switzerland)2021

Application of Phase-Reversal Fresnel Zone Plates for High-Resolution Robotic Ultrasonic Non-Destructive Evaluation.

Dmitry O Dolmatov, Daniel Tarrazó-Serrano, German A Filippov, Antonio Uris, Dmitry A Sednev

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.4field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 3 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Dmitry O DolmatovSchool of Non-Destructive Testing, National Research Tomsk Polytechnic University, 7 Savinykh Street, 634028 Tomsk, Russia.ORCID 0000-0003-1789-1519
Daniel Tarrazó-SerranoCentro de Tecnologías Físicas, Universitat Politècnica de València, Camí de Vera s/n, 46022 València, Spain.ORCID 0000-0001-9986-0884
German A FilippovSchool of Non-Destructive Testing, National Research Tomsk Polytechnic University, 7 Savinykh Street, 634028 Tomsk, Russia.ORCID 0000-0003-2321-7467
Antonio UrisCentro de Tecnologías Físicas, Universitat Politècnica de València, Camí de Vera s/n, 46022 València, Spain.ORCID 0000-0002-2005-2305
Dmitry A SednevNational Research Tomsk Polytechnic University, 30 Lenin Avenue, 634050 Tomsk, Russia.ORCID 0000-0001-9300-1392
National Research Tomsk State University · RUUniversitat Politècnica de València · ES

Funding

Generalitat Valenciana AICO/2020/139Russian Ministry of Science and Higher Education State Task "Research" (basic fundamental) project # FSWW-2020-0014Spanish Ministry of Science, Innovation and Universities RTI2018-100792-B-I00
6 · The paper itself

Abstract

Nowadays the development of automated inspection systems based on six degrees of freedom robotic manipulators is a highly relevant topic in ultrasonic non-destructive testing. One of the issues associated with such development is the problem of acquiring high-resolution results. In this article, the application Phase-Reversal Fresnel Zone Plates is considered for solving this problem. Such acoustic lenses can solve the task of high-resolution results acquisition by using a single unfocused transducer. Furthermore, Phase-Reversal Fresnel Zone Plates can provide the desired focusing depth with the fixed thickness of the coupling layer. It is important in the case of application of devices which provide localized coupling. In this paper a proper design of Phase-Reversal Fresnel Zone Plate was determined according to the conditions of planned experiments. Its efficiency was verified via the Finite Element Method modeling. In all performed experiments the relative error of flaws size estimation did not exceed 6% whereas the signal-to-noise ratio was not lower than 17.1 dB. Thus, experimental results demonstrate that the application of Phase-Reversal Fresnel Zone Plates allowed to obtain results with high lateral resolution and signal-to-noise ratio. These results demonstrate the reasonability of the development of devices that provide localized coupling and use Phase-Reversal Fresnel Zone Plates.

Indexed as

localized couplingPhase-Reversal Fresnel Zone Platesrobotic ultrasonic nondestructive evaluationultrasonic focusingultrasonic imagingultrasonic nondestructive testing

Identifiers

PMID34883791
PMCPMC8659810
OpenAlexW3216297475

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.