Evidence map›Paper›PMID 34883568›Full record

ArticlePolymers2021

A Customized Knee Antibiotic-Loaded PMMA Spacer: A Preliminary Design Analysis.

Marco Balato, Carlo Petrarca, Antonio Quercia, Aniello Riccio, Andrea Sellitto, Jessica Campi, Anna Borriello, Mauro Zarrelli, Giovanni Balato

Abstract read
In one paragraph

Article in Polymers, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Marco BalatoDepartment of Electrical Engineering and Information Technologies, University of Naples "Federico II", 80125 Napoli, NA, Italy.ORCID 0000-0003-0649-645X
Carlo PetrarcaDepartment of Electrical Engineering and Information Technologies, University of Naples "Federico II", 80125 Napoli, NA, Italy.ORCID 0000-0002-0986-6025
Antonio QuerciaDepartment of Electrical Engineering and Information Technologies, University of Naples "Federico II", 80125 Napoli, NA, Italy.
Aniello RiccioDepartment of Engineering, University of Campania "Luigi Vanvitelli", 81031 Aversa, CE, Italy.ORCID 0000-0001-7426-6803
Andrea SellittoDepartment of Engineering, University of Campania "Luigi Vanvitelli", 81031 Aversa, CE, Italy.ORCID 0000-0001-7766-8250
Jessica CampiDepartment of Engineering, University of Campania "Luigi Vanvitelli", 81031 Aversa, CE, Italy.
Anna BorrielloNational Research Council of Italy (CNR), Institute for Polymers, Composite and Biomedical Materials (IPCB), 80055 Portici, NA, Italy.ORCID 0000-0003-2214-3208
Mauro ZarrelliNational Research Council of Italy (CNR), Institute for Polymers, Composite and Biomedical Materials (IPCB), 80055 Portici, NA, Italy.ORCID 0000-0002-5018-5512
Giovanni BalatoDepartment of Public Health, University of Naples "Federico II", 80131 Naples, NA, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A preliminary design of customized antibiotic-loaded poly-methyl-methacrylate (ALPMMA) spacer characterized by an appropriate footprint according to the specific patient's anatomy and a reliable mechanical response to severe functional loads (i.e., level walking and 45° bent knee) is reported. The targeted virtual prototyping process takes origin from a novel patented 3D geometrical conceptualization characterized by added customization features and it is validated by a preliminary FEM-based analysis. Mechanical and thermomechanical properties of the antibiotic-doped orthopedic PMMA cement, which will be used for the future prototype manufacturing, were measured experimentally by testing samples taken during a real day-running orthopedic surgery and manufactured according to the surgeon protocol. FEM analysis results indicate that small area is subjected to intensive stresses, validating the proposed geometry from the mechanical point of view, under the two loading scenarios, moreover the value of safety margins results positive, and this is representative of the lower stress magnitude compared to the critical material limits. The experimental data confirm that the presence of antibiotic will last during the surgeon period moreover, the temperature dependent modulus of the bone cement is slightly affected by the body range temperature whereas it will drastically drop for higher temperature out the range of interest. A complete customization, according to a patient anatomy, and the corresponding real prototype spacer will be manufactured by 3D printing techniques, and it will be validated by destructive testing during the second stage of this activity before commercialization.

Indexed as

3D printingexperimental analysisFEM simulationsspacer

Identifiers

PMID34883568
PMCPMC8659215

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.