ArticleScientific reports2021
Preclinical evaluation of noncontact vital signs monitoring using real-time IR-UWB radar and factors affecting its accuracy.
Article in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 1 synthesis or guideline pooled it, 38 citations in OpenAlex.
- Systematic Literature Review Regarding Heart Rate and Respiratory Rate Measurement by Means of Radar Technology.Sensors (Basel, Switzerland) · 2024Pooled it
- Non-Contact Measurement of Human Vital Signs in Dynamic Conditions Using Microwave Techniques: A Review.Sensors (Basel, Switzerland) · 2026Review
- Radar-Based Detection of Obstructive Sleep Apnea: A Systematic Review and Network Meta-Analysis of Diagnostic Accuracy Across Frequency Bands.Diagnostics (Basel, Switzerland) · 2025Review
- A noncontact vital sign sensor demonstrating a strong correlation with an electrocardiogram electrode and a COScientific reports · 2025Article
- Separation of thoracic and abdominal measurements in neonatal vital sign monitoring using radar vision fusion system.Scientific reports · 2025Article
- Cellulose nanocrystal composite films for contactless moisture-electric conversion.RSC advances · 2025Article
- Smart furniture using radar technology for cardiac health monitoring.Scientific reports · 2025Article
- Model-based estimation of heart movements using microwave Doppler radar sensor.Journal of physiological anthropology · 2024Article
- Soli-enabled noncontact heart rate detection for sleep and meditation tracking.Scientific reports · 2023Article
- A SISO FMCW radar based on inherently frequency scanning antennas for 2-D indoor tracking of multiple subjects.Scientific reports · 2023Article
- Non-Contact VITAL Signs Monitoring of a Patient Lying on Surgical Bed Using Beamforming FMCW Radar.Sensors (Basel, Switzerland) · 2022Article
- Preclinical trial of noncontact anthropometric measurement using IR-UWB radar.Scientific reports · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Recently, noncontact vital sign monitors have attracted attention because of issues related to the transmission of contagious diseases. We developed a real-time vital sign monitor using impulse-radio ultrawideband (IR-UWB) radar with embedded processors and software; we then evaluated its accuracy in measuring heart rate (HR) and respiratory rate (RR) and investigated the factors affecting the accuracy of the radar-based measurements. In 50 patients visiting a cardiology clinic, HR and RR were measured using IR-UWB radar simultaneously with electrocardiography and capnometry. All patients underwent HR and RR measurements in 2 postures-supine and sitting-for 2 min each. There was a high agreement between the RR measured using radar and capnometry (concordance correlation coefficient [CCC] 0.925 [0.919-0.926]; upper and lower limits of agreement [LOA], - 2.21 and 3.90 breaths/min). The HR measured using radar was also in close agreement with the value measured using electrocardiography (CCC 0.749 [0.738-0.760]; upper and lower LOA, - 12.78 and 15.04 beats/min). Linear mixed effect models showed that the sitting position and an HR < 70 bpm were associated with an increase in the absolute biases of the HR, whereas the sitting position and an RR < 18 breaths/min were associated with an increase in the absolute biases of the RR. The IR-UWB radar sensor with embedded processors and software can measure the RR and HR in real time with high precision. The sitting position and a low RR or HR were associated with the accuracy of RR and HR measurement, respectively, using IR-UWB radar.
Indexed as
Identifiers
What OpenQuestion holds