ArticleJournal of clinical monitoring and computing2022
Continuous vital sign monitoring using a wearable patch sensor in obese patients: a validation study in a clinical setting.
Article in Journal of clinical monitoring and computing, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 19 citations in OpenAlex.
- Respiratory rate measurement by pressure variation in the high flow nasal cannula-system in healthy volunteers.Journal of clinical monitoring and computing · 2024Trial
- Accuracy of vital sign monitoring using a photoplethysmography upper arm wearable device in postoperative non-cardiac surgery patients: a prospective observational clinical validation study.Journal of clinical monitoring and computing · 2026Observational
- Wireless patches for continuous vital sign monitoring, symptoms and medication at the end-of-life in the palliative care unit: A prospective observational study.Journal of clinical monitoring and computing · 2026Observational
- The completeness, accuracy and impact on alerts, of wearable vital signs monitoring in hospitalised patients.BMC digital health · 2025Article
- Cloud-Integrated Smart Nanomembrane Wearables for Remote Wireless Continuous Health Monitoring of Postpartum Women.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024Article
- The value of C-reactive protein, leucocytes and vital signs in detecting major complications after oncological colorectal surgery.Langenbeck's archives of surgery · 2024Article
- Design and Fabrication of a Flexible Gravimetric Sensor Based on a Thin-Film Bulk Acoustic Wave Resonator.Sensors (Basel, Switzerland) · 2023Article
- Detecting Patient Deterioration Early Using Continuous Heart rate and Respiratory rate Measurements in Hospitalized COVID-19 Patients.Journal of medical systems · 2023Article
- Wearable Heart Rate Monitoring Device Communicating in 5G ISM Band for IoHT.Bioengineering (Basel, Switzerland) · 2023Article
- Article
- The Related Metabolic Diseases and Treatments of Obesity.Healthcare (Basel, Switzerland) · 2022Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Our aim was to determine the agreement of heart rate (HR) and respiratory rate (RR) measurements by the Philips Biosensor with a reference monitor (General Electric Carescape B650) in severely obese patients during and after bariatric surgery. Additionally, sensor reliability was assessed. Ninety-four severely obese patients were monitored with both the Biosensor and reference monitor during and after bariatric surgery. Agreement was defined as the mean absolute difference between both monitoring devices. Bland Altman plots and Clarke Error Grid analysis (CEG) were used to visualise differences. Sensor reliability was reflected by the amount, duration and causes of data loss. The mean absolute difference for HR was 1.26 beats per minute (bpm) (SD 0.84) during surgery and 1.84 bpm (SD 1.22) during recovery, and never exceeded the 8 bpm limit of agreement. The mean absolute difference for RR was 1.78 breaths per minute (brpm) (SD 1.90) during surgery and 4.24 brpm (SD 2.75) during recovery. The Biosensor's RR measurements exceeded the 2 brpm limit of agreement in 58% of the compared measurements. Averaging 15 min of measurements for both devices improved agreement. CEG showed that 99% of averaged RR measurements resulted in adequate treatment. Data loss was limited to 4.5% of the total duration of measurements for RR. No clear causes for data loss were found. The Biosensor is suitable for remote monitoring of HR, but not RR in morbidly obese patients. Future research should focus on improving RR measurements, the interpretation of continuous data, and development of smart alarm systems.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials