Evidence map›Paper›PMID 34877350›Full record

ArticleERJ open research2021

Quantification of aerosol dispersal from suspected aerosol-generating procedures.

Runar Strand-Amundsen, Christian Tronstad, Ole Elvebakk, Tormod Martinsen, Marius Dybwad, Egil Lingaas, Tor Inge Tønnessen

Open access · goldAbstract read
In one paragraph

Article in ERJ open research, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
1.0field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it, 7 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Observational
  5. Review
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Runar Strand-AmundsenDept of Clinical and Biomedical Engineering, Oslo University Hospital, Oslo, Norway.ORCID https://orcid.org/0000-0002-2224-9355
Christian TronstadDept of Clinical and Biomedical Engineering, Oslo University Hospital, Oslo, Norway.
Ole ElvebakkDept of Clinical and Biomedical Engineering, Oslo University Hospital, Oslo, Norway.
Tormod MartinsenDept of Clinical and Biomedical Engineering, Oslo University Hospital, Oslo, Norway.
Marius DybwadNorwegian Defence Research Establishment (FFI), Kjeller, Norway.
Egil LingaasDept of Infection Prevention, Oslo University Hospital - Rikshospitalet, Oslo, Norway.
Tor Inge TønnessenDept of Anaesthesiology, Division of Emergencies and Critical Care, Oslo University Hospital, Oslo, Norway.
Oslo University Hospital · NONorwegian Defence Research Establishment · NO

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundOxygen-delivering modalities like humidified high-flow nasal cannula (HFNC) and noninvasive positive-pressure ventilation (NIV) are suspected of generating aerosols that may contribute to transmission of disease such as coronavirus disease 2019. We sought to assess if these modalities lead to increased aerosol dispersal compared to the use of non-humidified low-flow nasal cannula oxygen treatment (LFNC).

methodsAerosol dispersal from 20 healthy volunteers using HFNC, LFNC and NIV oxygen treatment was measured in a controlled chamber. We investigated effects related to coughing and using a surgical face mask in combination with the oxygen delivering modalities. An aerodynamic particle sizer measured aerosol particles (APS3321, 0.3-20 µm) directly in front of the subjects, while a mesh of smaller particle sensors (SPS30, 0.3-10 µm) was distributed in the test chamber.

resultsNon-productive coughing led to significant increases in particle dispersal close to the face when using LFNC and HFNC but not when using NIV. HFNC or NIV did not lead to a statistically significant increase in aerosol dispersal compared to LFNC. With non-productive cough in a room without air changes, there was a significant drop in particle levels between 100 cm and 180 cm from the subjects.

conclusionsOur results indicate that using HFNC and NIV does not lead to increased aerosol dispersal compared to low-flow oxygen treatment, except in rare cases. For a subject with non-productive cough, NIV with double-limb circuit and non-vented mask may be a favourable choice to reduce the risk for aerosol spread.

Identifiers

PMID34877350
PMCPMC8474485
OpenAlexW3204350614

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.