Continuous Noninvasive Remote Automated Blood Pressure Monitoring With Novel Wearable Technology: A Preliminary Validation Study.
Article in JMIR mHealth and uHealth, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03493867 (Verification Protocol for The Cloud DX Vitaliti™ Continuous Vital Sign Monitor), which is not on this map. Cited by 8 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Verification Protocol for The Cloud DX Vitaliti™ Continuous Vital Sign Monitor (CVSM): Non-invasive Blood Pressure Component for Clinical Use and Self Measurement According to the American Safety in Medical Technology and the IEEE
Who cites it
8 citing papers in PubMed, 1 synthesis or guideline pooled it, 16 citations in OpenAlex.
- Wearable Blood Pressure Monitoring Devices: Understanding Heterogeneity in Design and Evaluation.IEEE transactions on bio-medical engineering · 2024Pooled it
- Consumer Smartwatch Technology in Health and Performance Research: Validity, Limitations, and Real-World Applications.Sensors (Basel, Switzerland) · 2026Review
- Feasibility and performance evaluation of PPG on a Galaxy Watch in continuous central blood pressure monitoring.European heart journal. Digital health · 2026Article
- Performance of a cuffless photoplethysmography-based device for continuous monitoring of blood pressure after cardiac surgery: a preliminary validation study.Journal of human hypertension · 2025Observational
- Article
- Human Factors, Human-Centered Design, and Usability of Sensor-Based Digital Health Technologies: Scoping Review.Journal of medical Internet research · 2024Article
- A prototype photoplethysmography-based cuffless device shows promising results in tracking changes in blood pressure.Frontiers in medical technology · 2024Article
- Accuracy of non-invasive cuffless blood pressure in the intensive care unit: Promises and challenges.Frontiers in medicine · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
27 authors at 7 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundWearable continuous monitoring biosensor technologies have the potential to transform postoperative care with early detection of impending clinical deterioration.
objectiveOur aim was to validate the accuracy of Cloud DX Vitaliti continuous vital signs monitor (CVSM) continuous noninvasive blood pressure (cNIBP) measurements in postsurgical patients. A secondary aim was to examine user acceptance of the Vitaliti CVSM with respect to comfort, ease of application, sustainability of positioning, and aesthetics.
methodsIncluded participants were ≥18 years old and recovering from surgery in a cardiac intensive care unit (ICU). We targeted a maximum recruitment of 80 participants for verification and acceptance testing. We also oversampled to minimize the effect of unforeseen interruptions and other challenges to the study. Validation procedures were according to the International Standards Organization (ISO) 81060-2:2018 standards for wearable, cuffless blood pressure (BP) measuring devices. Baseline BP was determined from the gold-standard ICU arterial catheter. The Vitaliti CVSM was calibrated against the reference arterial catheter. In static (seated in bed) and supine positions, 3 cNIBP measurements, each 30 seconds, were taken for each patient with the Vitaliti CVSM and an invasive arterial catheter. At the conclusion of each test session, captured cNIBP measurements were extracted using MediCollector BEDSIDE data extraction software, and Vitaliti CVSM measurements were extracted to a secure laptop through a cable connection. The errors of these determinations were calculated. Participants were interviewed about device acceptability.
resultsThe validation analysis included data for 20 patients. The average times from calibration to first measurement in the static position and to first measurement in the supine position were 133.85 seconds (2 minutes 14 seconds) and 535.15 seconds (8 minutes 55 seconds), respectively. The overall mean errors of determination for the static position were -0.621 (SD 4.640) mm Hg for systolic blood pressure (SBP) and 0.457 (SD 1.675) mm Hg for diastolic blood pressure (DBP). Errors of determination were slightly higher for the supine position, at 2.722 (SD 5.207) mm Hg for SBP and 2.650 (SD 3.221) mm Hg for DBP. The majority rated the Vitaliti CVSM as comfortable. This study was limited to evaluation of the device during a very short validation period after calibration (ie, that commenced within 2 minutes after calibration and lasted for a short duration of time).
conclusionsWe found that the Cloud DX's Vitaliti CVSM demonstrated cNIBP measurement in compliance with ISO 81060-2:2018 standards in the context of evaluation that commenced within 2 minutes of device calibration; this device was also well-received by patients in a postsurgical ICU setting. Future studies will examine the accuracy of the Vitaliti CVSM in ambulatory contexts, with attention to assessment over a longer duration and the impact of excessive patient motion on data artifacts and signal quality.
trial registrationClinicalTrials.gov NCT03493867; https://clinicaltrials.gov/ct2/show/NCT03493867.