Evidence map›Paper›PMID 34876396›Full record

ArticleJMIR mHealth and uHealth2022

Continuous Noninvasive Remote Automated Blood Pressure Monitoring With Novel Wearable Technology: A Preliminary Validation Study.

Michael H McGillion, Nazari Dvirnik, Stephen Yang, Emilie Belley-Côté, Andre Lamy, Richard Whitlock, Maura Marcucci, Flavia K Borges, Emmanuelle Duceppe, Carley Ouellette and 17 more

Registry-linked trialOpen access · goldAbstract read
In one paragraph

Article in JMIR mHealth and uHealth, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03493867 (Verification Protocol for The Cloud DX Vitaliti™ Continuous Vital Sign Monitor), which is not on this map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
1.9field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT03493867 nacompletednot on this map

Verification Protocol for The Cloud DX Vitaliti™ Continuous Vital Sign Monitor (CVSM): Non-invasive Blood Pressure Component for Clinical Use and Self Measurement According to the American Safety in Medical Technology and the IEEE

TypeinterventionalSponsorPopulation Health Research InstituteRan2018 to 2019Enrolled78ConditionsBlood PressureArmsVitaliti
3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it, 16 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Article
  4. Observational
  5. Computational and structural biotechnology journal · 2024
    Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

27 authors at 7 institutions in 1 country.

Michael H McGillion *School of Nursing, McMaster University, Hamilton, ON, Canada.ORCID 0000-0002-1343-7012
Nazari Dvirnik *Population Health Research Institute, Hamilton, ON, Canada.ORCID 0000-0002-1553-9805
Stephen Yang *McGill University, Montreal, QC, Canada.ORCID 0000-0003-3859-5110
Emilie Belley-CôtéPopulation Health Research Institute, Hamilton, ON, Canada.ORCID 0000-0002-5071-076X
Andre LamyPopulation Health Research Institute, Hamilton, ON, Canada.ORCID 0000-0003-2777-7621
Richard WhitlockPopulation Health Research Institute, Hamilton, ON, Canada.ORCID 0000-0002-6863-5884
Maura MarcucciPopulation Health Research Institute, Hamilton, ON, Canada.ORCID 0000-0002-8468-7991
Flavia K BorgesPopulation Health Research Institute, Hamilton, ON, Canada.ORCID 0000-0001-5377-7612
Emmanuelle DuceppeDepartment of Medicine, Faculty of Nedicine, Université de Montréal, Montréal, QC, Canada.ORCID 0000-0002-1457-2945
Carley OuelletteSchool of Nursing, McMaster University, Hamilton, ON, Canada.ORCID 0000-0003-3242-6164
Marissa BirdSchool of Nursing, McMaster University, Hamilton, ON, Canada.ORCID 0000-0003-2188-0767
Sandra L CarrollSchool of Nursing, McMaster University, Hamilton, ON, Canada.ORCID 0000-0003-3936-6993
David ConenPopulation Health Research Institute, Hamilton, ON, Canada.ORCID 0000-0002-2459-5251
Jean-Eric TarrideFaculty of Health Sciences, McMaster University, Hamilton, ON, Canada.ORCID 0000-0003-2913-7580
Prathiba HarshaResearch and Innovation, Hamilton Health Sciences, Hamilton, ON, Canada.ORCID 0000-0001-6562-0479
Ted ScottResearch and Innovation, Hamilton Health Sciences, Hamilton, ON, Canada.ORCID 0000-0002-6190-050X
Amber GoodPopulation Health Research Institute, Hamilton, ON, Canada.ORCID 0000-0002-1714-7872
Krysten GregusResearch and Innovation, Hamilton Health Sciences, Hamilton, ON, Canada.ORCID 0000-0003-0919-6153
Karla SanchezPopulation Health Research Institute, Hamilton, ON, Canada.ORCID 0000-0003-0176-9666
Pamela BenoitCardiac and Vascular Intensive Care Unit, Hamilton Health Sciences, Hamilton, ON, Canada.ORCID 0000-0001-8121-5481
Julian OwenCardiac and Vascular Intensive Care Unit, Hamilton Health Sciences, Hamilton, ON, Canada.ORCID 0000-0001-6939-8748
Valerie HarveyPopulation Health Research Institute, Hamilton, ON, Canada.ORCID 0000-0002-3075-4036
Elizabeth PeterUniversity of Toronto, Toronto, ON, Canada.ORCID 0000-0002-8155-216X
Jeremy PetchPopulation Health Research Institute, Hamilton, ON, Canada.ORCID 0000-0003-1614-1046
Jessica VincentPopulation Health Research Institute, Hamilton, ON, Canada.ORCID 0000-0002-2356-8876
Michelle GrahamUniversity of Alberta, Edmonton, AB, Canada.ORCID 0000-0003-0708-7957
P J DevereauxPopulation Health Research Institute, Hamilton, ON, Canada.ORCID 0000-0003-2935-637X
Population Health Research Institute · CAHamilton Health Sciences · CAMcMaster University · CAUniversity of Toronto · CAMcGill University · CAUniversité de Montréal · CAUniversity of Alberta · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundWearable continuous monitoring biosensor technologies have the potential to transform postoperative care with early detection of impending clinical deterioration.

objectiveOur aim was to validate the accuracy of Cloud DX Vitaliti continuous vital signs monitor (CVSM) continuous noninvasive blood pressure (cNIBP) measurements in postsurgical patients. A secondary aim was to examine user acceptance of the Vitaliti CVSM with respect to comfort, ease of application, sustainability of positioning, and aesthetics.

methodsIncluded participants were ≥18 years old and recovering from surgery in a cardiac intensive care unit (ICU). We targeted a maximum recruitment of 80 participants for verification and acceptance testing. We also oversampled to minimize the effect of unforeseen interruptions and other challenges to the study. Validation procedures were according to the International Standards Organization (ISO) 81060-2:2018 standards for wearable, cuffless blood pressure (BP) measuring devices. Baseline BP was determined from the gold-standard ICU arterial catheter. The Vitaliti CVSM was calibrated against the reference arterial catheter. In static (seated in bed) and supine positions, 3 cNIBP measurements, each 30 seconds, were taken for each patient with the Vitaliti CVSM and an invasive arterial catheter. At the conclusion of each test session, captured cNIBP measurements were extracted using MediCollector BEDSIDE data extraction software, and Vitaliti CVSM measurements were extracted to a secure laptop through a cable connection. The errors of these determinations were calculated. Participants were interviewed about device acceptability.

resultsThe validation analysis included data for 20 patients. The average times from calibration to first measurement in the static position and to first measurement in the supine position were 133.85 seconds (2 minutes 14 seconds) and 535.15 seconds (8 minutes 55 seconds), respectively. The overall mean errors of determination for the static position were -0.621 (SD 4.640) mm Hg for systolic blood pressure (SBP) and 0.457 (SD 1.675) mm Hg for diastolic blood pressure (DBP). Errors of determination were slightly higher for the supine position, at 2.722 (SD 5.207) mm Hg for SBP and 2.650 (SD 3.221) mm Hg for DBP. The majority rated the Vitaliti CVSM as comfortable. This study was limited to evaluation of the device during a very short validation period after calibration (ie, that commenced within 2 minutes after calibration and lasted for a short duration of time).

conclusionsWe found that the Cloud DX's Vitaliti CVSM demonstrated cNIBP measurement in compliance with ISO 81060-2:2018 standards in the context of evaluation that commenced within 2 minutes of device calibration; this device was also well-received by patients in a postsurgical ICU setting. Future studies will examine the accuracy of the Vitaliti CVSM in ambulatory contexts, with attention to assessment over a longer duration and the impact of excessive patient motion on data artifacts and signal quality.

trial registrationClinicalTrials.gov NCT03493867; https://clinicaltrials.gov/ct2/show/NCT03493867.

Indexed as

Blood Pressure DeterminationWearable Electronic DevicesAdolescentBlood PressureHumansMonitoring, Physiologicaccuracybiosensorblood pressurecontinuous non-invasive blood pressure monitoringcontinuous vital signs monitormHealthmonitoringusabilityvalidationvalidation studyvital signwearable

Identifiers

PMID34876396
PMCPMC8922156
OpenAlexW3213490522

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.