Evidence map›Paper›PMID 34874017›Full record

ArticleBiomedical physics & engineering express2021

Bias-voltage dependent operational characteristics of a fully spectroscopic pixelated cadmium telluride detector system within an experimental benchtop x-ray fluorescence imaging setup.

Hem Moktan, Raj Kumar Panta, Sang Hyun Cho

Abstract read
In one paragraph

Article in Biomedical physics & engineering express, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Monte Carlo Modeling of An Experimental Benchtop L-shell X-ray Fluorescence Imaging/CT System Adopting Two Silicone Drift Detectors.Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Hem MoktanDepartment of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, United States of America.
Raj Kumar PantaDepartment of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, United States of America.
Sang Hyun ChoDepartment of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, United States of America.ORCID 0000-0002-6357-5042

Funding

Towards in vivo imaging with benchtop x-ray fluorescence computed tomographyR01EB020658 · NIBIB · UNIVERSITY OF TX MD ANDERSON CAN CTR · PI CHO, SANG HYUN · 2016 to 2019
$3.0M
NIBIB NIH HHS R01 EB020658
6 · The paper itself

Abstract

Commercially available fully spectroscopic pixelated cadmium telluride (CdTe) detector systems have been adopted lately for benchtop x-ray fluorescence (XRF) imaging/computed tomography (XFCT) of objects containing metal nanoprobes such as gold nanoparticles (GNPs). To date, however, some important characteristics of such detector systems under typical operating conditions of benchtop XRF/XFCT imaging systems are not well known. One important but poorly studied characteristic is the effect of detector bias-voltage on photon counting efficiency, energy resolution, and the resulting material detection limit. In this work, therefore, we investigated these characteristics for a commercial pixelated detector system adopting a 1-mm-thick CdTe sensor (0.25-mm pixel-pitch), known as HEXITEC, incorporated into an experimental benchtop cone-beam XFCT system with parallel-hole detector collimation. The detector system, operated at different bias-voltages, was used to acquire the gold XRF/Compton spectra from 1.0 wt% GNP-loaded phantom irradiated with 125 kVp x-rays filtered by 1.8-mm Tin. At each bias-voltage, the gold XRF signal, and the full-width-at-half-maximum at gold K

Indexed as

Cadmium CompoundsMetal NanoparticlesQuantum DotsGoldOptical ImagingTelluriumX-RaysCadmium Compoundscadmium tellurideGoldTelluriumbenchtop x-ray fluorescence imagingdetector bias-voltage optimizationgold nanoparticlespixelated cadmium telluride detectors

Identifiers

PMID34874017
PMCPMC8675630

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked