Evidence map›Paper›PMID 34871385›Full record

ArticleEuropean heart journal. Cardiovascular Imaging2022

Does mechanical dyssynchrony in addition to QRS area ensure sustained response to cardiac resynchronization therapy?

Philippe C Wouters, Wouter M van Everdingen, Kevin Vernooy, Bastiaan Geelhoed, Cornelis P Allaart, Michiel Rienstra, Alexander H Maass, Marc A Vos, Frits W Prinzen, Mathias Meine and 1 more

Registry-linked trialOpen access · hybridAbstract read
In one paragraph

Article in European heart journal. Cardiovascular Imaging, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05993585 (The Effects of Cardiac Resynchronisation Therapy on the Frank Starling Mechanism in Patients With Heart Failure), which is not on this map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
0.9field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05993585 naunknown statusnot on this mapstarted 2024, after this paper: background citation

The Effects of Cardiac Resynchronisation Therapy on the Frank Starling Mechanism in Patients With Heart Failure

TypeinterventionalSponsorGuy's and St Thomas' NHS Foundation TrustRan2024 to 2025Enrolled40ConditionsPacemaker, HeartfailureArmsTest Of The Frank Starling Mechanism - Adjustment Of Av Delay And Measurement Of Pre-load -Control, Other: Test Of The Frank Starling Mechanism - Adjustment Of Av Delay And Measurement Of Pre-load -CRT
3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it, 10 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. The evolving state of cardiac resynchronization therapy and conduction system pacing: 25 years of research at EP Europace journal.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2023
    Review
  5. Article
  6. Electromechanical factors associated with favourable outcome in cardiac resynchronization therapy.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2023
    Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 5 institutions in 3 countries.

Philippe C WoutersDepartment of Cardiology, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands.ORCID 0000-0002-3406-4083
Wouter M van EverdingenDepartment of Cardiology, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands.ORCID 0000-0003-3577-8923
Kevin VernooyDepartment of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Centre+ (MUMC+), 6229 HX Maastricht, The Netherlands.ORCID 0000-0002-8818-5964
Bastiaan GeelhoedDepartment of Cardiology, Thoraxcentre, University of Groningen, University Medical Center Groningen, 9713 GZ Groningen, The Netherlands.
Cornelis P AllaartDepartment of Cardiology, Amsterdam University Medical Center, Location VU University Medical Center, 1081 HV Amsterdam, The Netherlands.ORCID 0000-0002-0506-9512
Michiel RienstraDepartment of Cardiology, Thoraxcentre, University of Groningen, University Medical Center Groningen, 9713 GZ Groningen, The Netherlands.ORCID 0000-0002-2581-070X
Alexander H MaassDepartment of Cardiology, Thoraxcentre, University of Groningen, University Medical Center Groningen, 9713 GZ Groningen, The Netherlands.ORCID 0000-0003-2556-4534
Marc A VosDepartment of Medical Physiology, University of Utrecht, 3584 CM Utrecht, The Netherlands.
Frits W PrinzenDepartment of Physiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, 6229 ER Masstricht, The Netherlands.ORCID 0000-0001-8888-5090
Mathias MeineDepartment of Cardiology, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands.ORCID 0000-0002-1102-2155
Maarten J CramerDepartment of Cardiology, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands.ORCID 0000-0002-6041-6759
Heidelberg University · DEUniversity Medical Center Groningen · NLMaastricht University · NLRadboud University Nijmegen · NLUniversity Medical Center Utrecht · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimsJudicious patient selection for cardiac resynchronization therapy (CRT) may further enhance treatment response. Progress has been made by using improved markers of electrical dyssynchrony and mechanical discoordination, using QRSAREA, and systolic rebound stretch of the septum (SRSsept) or systolic stretch index (SSI), respectively. To date, the relation between these measurements has not yet been investigated. METHODS AND

resultsA total of 240 CRT patients were prospectively enrolled from six centres. Patients underwent standard 12-lead electrocardiography, and echocardiography, at baseline, 6-month, and 12-month follow-up. QRSAREA was derived using vectorcardiography, and SRSsept and SSI were measured using strain-analysis. Reverse remodelling was measured as the relative decrease in left ventricular end-systolic volume, indexed to body surface area (ΔLVESVi). Sustained response was defined as ≥15% decrease in LVESVi, at both 6- and 12-month follow-up. QRSAREA and SRSsept were both strong, multivariable adjusted, variables associated with reverse remodelling. SRSsept was associated with response, but only in patients with QRSAREA ≥ 120 μVs (AUC = 0.727 vs. 0.443). Combined presence of SRSsept ≥ 2.5% and QRSAREA ≥ 120 μVs significantly increased reverse remodelling compared with high QRSAREA alone (ΔLVESVi 38 ± 21% vs. 22 ± 21%). As a result, 92% of left bundle branch block (LBBB)-patients with combined electrical and mechanical dysfunction were 'sustained' volumetric responders, as opposed to 51% with high QRSAREA alone.

conclusionParameters of mechanical dyssynchrony are better associated with response in the presence of a clear underlying electrical substrate. Combined presence of high SRSsept and QRSAREA, but not high QRSAREA alone, ensures a sustained response after CRT in LBBB patients.

Indexed as

Cardiac Resynchronization TherapyHeart FailureArrhythmias, CardiacBundle-Branch BlockEchocardiographyElectrocardiographyHumansTreatment Outcomecardiac resynchronization therapyechocardiographyheart failureQRS areastrain imaging

Identifiers

PMID34871385
PMCPMC9671288
OpenAlexW4200462117

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390