ArticleScanning2021
Highly Reliable Method to Obtain a Correlation Coefficient Unaffected by the SEM Noise Component for Examining the Degree of Specimen Damage due to Electron Beam Irradiation.
Article in Scanning, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A correlation coefficient is often used as a measure of the strength of a linear relationship (i.e., the degree of similarity) between two sets of data in a variety of fields. However, in the field of scanning electron microscopy (SEM), it is frequently difficult to properly use the correlation coefficient because SEM images generally include severe noise, which affects the measurement of this coefficient. The current study describes a method of obtaining a correlation coefficient that is unaffected by SEM noise in principle. This correlation coefficient is obtained from a total of four SEM images, comprising two sets of two images with identical views, by calculating several covariance values. Numerical experiments confirm that the measured correlation coefficients obtained using the proposed method for noisy images are equal to those for noise-free images. Furthermore, the present method can be combined with a highly accurate and noise-robust position alignment as needed. As one application, we show that it is possible to immediately examine the degree of specimen damage due to electron beam irradiation during a certain SEM observation, which has been difficult until now.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.