Evidence map›Paper›PMID 34853781›Full record

ArticleERJ open research2021

Pilot study on nocturnal monitoring of crackles in children with pneumonia.

Wilfried Nikolaizik, Lisa Wuensch, Monika Bauck, Volker Gross, Keywan Sohrabi, Andreas Weissflog, Olaf Hildebrandt, Ulrich Koehler, Stefanie Weber

Open access · goldAbstract read
In one paragraph

Article in ERJ open research, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 77% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Wilfried NikolaizikDept of Pediatric Pulmonology, Children's Hospital, Philipps-University, Marburg, Germany.
Lisa WuenschDept of Pediatric Pulmonology, Children's Hospital, Philipps-University, Marburg, Germany.
Monika BauckDept of Pediatric Pulmonology, Children's Hospital, Philipps-University, Marburg, Germany.
Volker GrossFaculty of Health Sciences, University of Applied Sciences, Giessen, Germany.
Keywan SohrabiFaculty of Health Sciences, University of Applied Sciences, Giessen, Germany.
Andreas WeissflogThora Tech GmbH, Giessen, Germany.
Olaf HildebrandtDivision of Respiratory and Critical Care Medicine, Philipps-University, Marburg, Germany.
Ulrich KoehlerDivision of Respiratory and Critical Care Medicine, Philipps-University, Marburg, Germany.
Stefanie WeberDept of Pediatric Pulmonology, Children's Hospital, Philipps-University, Marburg, Germany.
Philipps University of Marburg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe clinical diagnosis of pneumonia is usually based on crackles at auscultation, but it is not yet clear what kind of crackles are the characteristic features of pneumonia in children. Lung sound monitoring can be used as a "longtime stethoscope". Therefore, it was the aim of this pilot study to use a lung sound monitor system to detect crackles and to differentiate between fine and coarse crackles in children with acute pneumonia. The change of crackles during the course of the disease shall be investigated in a follow-up study. PATIENTS AND

methodsCrackles were recorded overnight from 22:00 to 06:00 h in 30 children with radiographically confirmed pneumonia. The data for a total of 28 800 recorded 30-s epochs were audiovisually analysed for fine and coarse crackles.

resultsFine crackles and coarse crackles were recognised in every patient with pneumonia, but the number of epochs with and without crackles varied widely among the different patients: fine crackles were detected in 40±22% (mean±sd), coarse crackles in 76±20%. The predominant localisation of crackles as recorded during overnight monitoring was in accordance with the radiographic infiltrates and the classical auscultation in most patients. The distribution of crackles was fairly equal throughout the night. However, there were time periods without any crackle in the single patients so that the diagnosis of pneumonia might be missed at sporadic auscultation.

conclusionNocturnal monitoring can be beneficial to reliably detect fine and coarse crackles in children with pneumonia.

Identifiers

PMID34853781
PMCPMC8628192
OpenAlexW3211121566

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked