Evidence map›Paper›PMID 34853376›Full record

Trial reportScientific reports2021

Accuracy of single intravenous access iohexol GFR in children is hampered by marker contamination.

Thea Tislevoll Eide, Karl Ove Hufthammer, Atle Brun, Damien Brackman, Einar Svarstad, Camilla Tøndel

Registry-linked trialOpen access · goldAbstract readClinical Trial
In one paragraph

Trial report in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT01092260 (Glomerular Filtration Rate in Children - a Methodological Study With Iohexol Clearance), which is not on this map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 79% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT01092260 completednot on this map

Glomerular Filtration Rate in Children - a Methodological Study With Iohexol Clearance

TypeobservationalSponsorHaukeland University HospitalRan2010 to 2011Enrolled96ConditionsRenal Function Disorder
3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Thea Tislevoll EideRenal Research Group, Department of Clinical Medicine, University of Bergen, Bergen, Norway.
Karl Ove HufthammerCentre for Clinical Research, Haukeland University Hospital, Bergen, Norway.
Atle BrunLaboratory for Clinical Biochemistry, Haukeland University Hospital, Bergen, Norway.
Damien BrackmanDepartment of Pediatrics, Haukeland University Hospital, 5021, Bergen, Norway.
Einar SvarstadRenal Research Group, Department of Clinical Medicine, University of Bergen, Bergen, Norway.
Camilla TøndelRenal Research Group, Department of Clinical Medicine, University of Bergen, Bergen, Norway. camilla.tondel@helse-bergen.no.
University of Bergen · NOHaukeland University Hospital · NO

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Measurement of glomerular filtration rate (GFR) in children by iohexol injection and blood sampling from the contralateral arm is widely used. A single intravenous access for iohexol injection and subsequent blood sampling has the obvious advantages of being less painful and easier to perform. The purpose of our study was to determine if blood samples drawn from the injection access are feasible and accurate for iohexol GFR (iGFR) measurements. Thirty-one children, median age 10.5 (range 6-17) years, with chronic kidney disease were given a bolus of iohexol followed by extended saline flushing and subsequent venous blood samples collected from the injection access as well as from a cannula in the contralateral arm, the latter serving as the reference method. Paired venous blood samples were collected at four time points (2, 3, 3.5 and 4 h) after the iohexol bolus. Blood sample discarding preceded and saline flushing followed each blood sampling to avoid marker contamination. iGFR based on samples drawn from the injection access at 2 and 3 h showed significantly lower iGFR than measurement from the contralateral arm (p < 0.01). Singlepoint iGFR did not differ significantly after 3-4 repeated procedures of blood discarding and saline flusing (3.5 and 4 h). Despite thorough saline flushing there is still a relatively high risk of falsely low iGFR due to marker contamination in blood samples from the injection site. Hence, blood sampling from a second intravenous access is recommended for routine iohexol GFR measurements in children.Clinical trial registration: ClinicalTrials.gov, Identifier NCT01092260, https://clinicaltrials.gov/ct2/show/NCT01092260?term=tondel&rank=2 .

Indexed as

Glomerular Filtration RateAdministration, IntravenousAdolescentBlood Specimen CollectionChildHumansIohexolMetabolic Clearance RateRenal Insufficiency, ChronicIohexol

Identifiers

PMID34853376
PMCPMC8636567
OpenAlexW3216635871

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.