Validation of Monte Carlo dose calculation algorithm for CyberKnife multileaf collimator.

Maude Gondré, Fanny Marsolat, Jean Bourhis, François Bochud, Raphaël Moeckli

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.6field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. A novel Monte Carlo (MC) dose model for small MLC fields of the cyberknifeJournal of applied clinical medical physics · 2023
    Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Maude GondréInstitute of Radiation Physics, Lausanne University Hospital and Lausanne University, Lausanne, Switzerland.
Fanny MarsolatInstitute of Radiation Physics, Lausanne University Hospital and Lausanne University, Lausanne, Switzerland.
Jean BourhisRadio-Oncology Department, Lausanne University Hospital and Lausanne University, Lausanne, Switzerland.
François BochudInstitute of Radiation Physics, Lausanne University Hospital and Lausanne University, Lausanne, Switzerland.
Raphaël MoeckliInstitute of Radiation Physics, Lausanne University Hospital and Lausanne University, Lausanne, Switzerland.ORCID https://orcid.org/0000-0002-5885-934X
Institute of Radiation PhysicsUniversity of Lausanne · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo commission and evaluate the Monte Carlo (MC) dose calculation algorithm for the CyberKnife equipped with a multileaf collimator (MLC).

methodsWe created a MC model for the MLC using an integrated module of the CyberKnife treatment planning software (TPS). Two parameters could be optimized: the maximum energy and the source full width at half-maximum (FWHM). The optimization was performed by minimizing the differences between the measured and the MC calculated tissue phantom ratios and profiles. MLC plans were calculated in the TPS with the MC algorithm and irradiated on different phantoms. The dose was measured using an A1SL ionization chamber and EBT3 Gafchromic films, and then compared to the TPS dose to obtain dose differences (ΔD). Finally, patient-specific quality assurances (QA) were performed with global gamma index criteria of 3%/1 mm.

resultsThe maximum energy and source FWHM showing the best agreement with measurements were 6.4 MeV and 1.8 mm. The output factors calculated with these parameters gave an agreement within ±1% with measurements. The ΔD showed that MC model systematically underestimated the dose with an average of -1.5% over all configurations tested. For depths deeper than 12 cm, the ΔD increased, up to -3.0% (maximum at 15.5 cm depth).

conclusionsThe MC model for MLC of CyberKnife is clinically acceptable but underestimates the delivered dose by an average of -1.5%. Therefore, we recommend using the MC algorithm with the MLC only in heterogeneous regions and for shallow-seated tumors.

Indexed as

AlgorithmsRadiotherapy Planning, Computer-AssistedHumansMonte Carlo MethodPhantoms, ImagingRadiotherapy DosagecommissioningCyberKnifeMonte Carlo dose algorithmmultileaf collimator

Identifiers

PMID34851007
PMCPMC8833269
OpenAlexW3215100776

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.