Evidence map›Paper›PMID 34848292›Full record

ArticleAmerican journal of infection control2022

Use of carbon dioxide measurements to assess ventilation in an acute care hospital.

Wilson Ha, Trina F Zabarsky, Elizabeth C Eckstein, Heba Alhmidi, Annette L Jencson, Jennifer L Cadnum, Curtis J Donskey

Abstract read
In one paragraph

Article in American journal of infection control, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Challenging cases in infection prevention and control: proceedings from SHEA Spring 2025.Antimicrobial stewardship & healthcare epidemiology : ASHE · 2026
    Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Wilson HaJohn Carroll University, University Heights, OH.
Trina F ZabarskyInfection Control Department, Louis Stokes Cleveland VA Medical Center, Cleveland, OH.
Elizabeth C EcksteinInfection Control Department, Louis Stokes Cleveland VA Medical Center, Cleveland, OH.
Heba AlhmidiResearch Service, Louis Stokes Cleveland VA Medical Center, Cleveland, OH.
Annette L JencsonResearch Service, Louis Stokes Cleveland VA Medical Center, Cleveland, OH.
Jennifer L CadnumResearch Service, Louis Stokes Cleveland VA Medical Center, Cleveland, OH.
Curtis J DonskeyGeriatric Research, Education, and Clinical Center, Louis Stokes Cleveland VA Medical Center, Cleveland, OH; Case Western Reserve University School of Medicine, Cleveland, OH. Electronic address: Curtis.Donskey@va.gov.

Funding

Microbiologic impact of medical therapies for recurrent Clostridium difficile infectionI01CX001848 · VA · LOUIS STOKES CLEVELAND VA MEDICAL CENTER · PI DONSKEY, CURTIS · 2019 to 2023
–
CSRD VA I01 CX001848
6 · The paper itself

Abstract

Poorly ventilated indoor spaces pose a risk for airborne transmission of SARS-CoV-2. We measured carbon dioxide levels in a multiple areas in an acute care hospital to assess the adequacy of ventilation. Carbon dioxide levels remained below 800 parts per million in most areas but exceeded this level in a small conference room with 8 occupants, an office with 3 occupants, and a bathroom with 2 occupants. Measuring carbon dioxide levels could provide a simple means for healthcare facilities to assess the adequacy of ventilation.

Indexed as

Air Pollution, IndoorCOVID-19Carbon DioxideHospitalsHumansSARS-CoV-2VentilationCarbon DioxideAerosolCOVID-19Transmission

Identifiers

PMID34848292
PMCPMC8627286

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.