Evidence map›Paper›PMID 34841219›Full record

ArticleIEEE transactions on medical robotics and bionics2021

Bayesian Optimization for Design of Multi-Actuator Soft Catheter Robots.

Seyede Fatemeh Ghoreishi, Ryan D Sochol, Dheeraj Gandhi, Axel Krieger, Mark Fuge

Abstract read
In one paragraph

Article in IEEE transactions on medical robotics and bionics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. One-Piece 3D-Printed Pneumatic Catheter: Dual-Segment Design with Integrated Robotics Control for Endovascular Interventions.IEEE International Conference on Soft Robotics. IEEE International Conference on Soft Robotics · 2024
    Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Seyede Fatemeh GhoreishiInstitute for Systems Research, University of Maryland, College Park, MD 20742 USA.
Ryan D SocholDepartment of Mechanical Engineering, University of Maryland, College Park, MD 20742 USA.
Dheeraj GandhiDepartment of Diagnostic Radiology and Nuclear Medicine, University of Maryland, School of Medicine, Baltimore, MD 21201 USA.
Axel KriegerDepartment of Mechanical Engineering, Johns Hopkins University, Baltimore, MD 21218 USA.
Mark FugeDepartment of Mechanical Engineering, University of Maryland, College Park, MD 20742 USA.

Funding

Patient specific 3D printed tissue engineered vascular graft for aortic reconstruction designed by artificial intelligence algorithm.R01HL143468 · NHLBI · UNIVERSITY OF CHICAGO · PI FUGE, MARK, HIBINO, NARUTOSHI · 2018 to 2021
$2.7M
NHLBI NIH HHS R01 HL143468
6 · The paper itself

Abstract

Catheter-based diagnosis and therapy have grown increasingly in recent years due to their improved clinical outcomes including decreased morbidity, shorter recovery time and minimally invasiveness compared to open surgeries. Although the scalability, customizability, and diversity of soft catheter robots are widely recognized, designers and roboticists still lack comprehensive techniques for modeling and designing them. This difficulty arises due to their continuum nature, which makes characterizing the properties and predicting a soft catheter's behavior challenging, complicating robot design tasks. In this paper, we propose modeling multi-actuator soft catheters to enable alignment with desired vessel shapes near the target area. We develop mathematical models to simulate the catheter's positioning due to the moments exerted by multiple pneumatic actuators along the catheter and use those models to compare optimization approaches that can achieve catheter alignment along a desired vessel shape. Specifically, our approach proposes finding the optimal geometric and material properties for a multi-actuator soft catheter robot using a bi-level optimization framework. The upper-level optimization process uses a modified Bayesian technique to seek the optimal geometric and material properties of the soft catheter, which minimize the deviance of the actuated catheter from a desired vessel shape, while the lower-level optimization process uses a gradient-based technique to obtain the actuator moments required to achieve that vessel shape. The results demonstrate the capability of our proposed multi-actuator soft catheter to align with the desired vessel shapes, and show that the proposed framework which is in the context of Bayesian optimization has the potential to expedite the design process.

Indexed as

Bi-Level OptimizationDesignSoft Catheter Robots

Identifiers

PMID34841219
PMCPMC8612453

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.