Evidence map›Paper›PMID 34841161›Full record

ArticleACS omega2021

Electrochemical Sensor for the Detection of 1-Hydroxypyrene Based on Composites of PAMAM-Regulated Chromium-Centered Metal-Organic Framework Nanoparticles and Graphene Oxide.

Hong Cui, Shuaishuai Cui, Qiuju Tian, Siyuan Zhang, Mingxiu Wang, Ping Zhang, Yunfeng Liu, Jialing Zhang, Xiangjun Li

Open access · goldAbstract read
In one paragraph

Article in ACS omega, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.2field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 31 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. A UiO-66-NHBiosensors · 2023
    Article
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Hong CuiSchool of Public Health, Shanxi Medical University, 56 Xinjian South Road, Taiyuan 030001, China.ORCID https://orcid.org/0000-0001-7373-4804
Shuaishuai CuiSchool of Public Health, Shanxi Medical University, 56 Xinjian South Road, Taiyuan 030001, China.
Qiuju TianSchool of Public Health, Shanxi Medical University, 56 Xinjian South Road, Taiyuan 030001, China.
Siyuan ZhangSchool of Public Health, Shanxi Medical University, 56 Xinjian South Road, Taiyuan 030001, China.
Mingxiu WangSchool of Public Health, Shanxi Medical University, 56 Xinjian South Road, Taiyuan 030001, China.
Ping ZhangSchool of Public Health, Shanxi Medical University, 56 Xinjian South Road, Taiyuan 030001, China.
Yunfeng LiuSchool of Public Health, Shanxi Medical University, 56 Xinjian South Road, Taiyuan 030001, China.
Jialing ZhangSchool of Public Health, Shanxi Medical University, 56 Xinjian South Road, Taiyuan 030001, China.
Xiangjun LiSchool of Chemical Sciences, University of Chinese Academy of Sciences, 19A Yuquan Road, Beijing 100049, China.ORCID https://orcid.org/0000-0001-9919-1238
Shanxi Medical University · CNUniversity of Chinese Academy of Sciences · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A nanocomposite was formed by combining graphene oxide (GO) with chromium-centered metal-organic framework (Cr-MOF) nanoparticles regulated by the dendrimer polyamidoamine (PAMAM). PAMAM can successfully regulate the synthesis of Cr-MOF; in doing so, the size of Cr-MOF is reduced, its original morphology is maintained, and it has good crystallinity. A simple ultrasonication method was used to make the Cr-MOF/GO hybrid nanocomposite. Various characterization methods confirmed the successful synthesis of PAMAM/Cr-MOF/GO nanocomposites. The PAMAM/Cr-MOF/ERGO modified electrode could be used with cyclic voltammetry (CV) and differential pulse voltammetry (DPV) to study the electrochemical behaviors of 1-hydroxypyrene (1-OHPyr). The results indicated that the constructed PAMAM/Cr-MOF/ERGO electrochemical sensor had a significantly enhanced electrocatalytic effect on the electrochemical reduction of 1-OHPyr compared with the sensors with no PAMAM and the ERGO sensor, which could be ascribed to the synergetic effect from the high porosity of Cr-MOF and the high conductivity of ERGO, as well as the further electron transport action of the nanocomposite. Under the optimal conditions, the reduction peak current and concentration of 1-OHPyr showed a good linear relationship in the range of 0.1-1.0 and 1.0-6.0 μM, and the detection limit of 1-OHPyr was calculated to be 0.075 μM. Moreover, the PAMAM/Cr-MOF/ERGO electrochemical sensor constructed in this paper can be expected to provide some instructions for the construction of electrochemical sensing platforms and wider potential applications.

Identifiers

PMID34841161
PMCPMC8613871
OpenAlexW3214348121

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.