Evidence map›Paper›PMID 34836522›Full record

ArticleBMC musculoskeletal disorders2021

Pedicle screw accuracy in thoracolumbar fractures- is routine postoperative CT scan necessary?

R Aigner, C Bichlmaier, L Oberkircher, T Knauf, A König, P Lechler, S Ruchholtz, M Frink

Abstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

R AignerCenter for Orthopaedics and Trauma Surgery, University Hospital Giessen and Marburg GmbH, Location Marburg, Baldingerstraße, D-35043, Marburg, Germany. aignerr@med.uni-marburg.de.
C BichlmaierCenter for Orthopaedics and Trauma Surgery, University Hospital Giessen and Marburg GmbH, Location Marburg, Baldingerstraße, D-35043, Marburg, Germany.
L OberkircherCenter for Orthopaedics and Trauma Surgery, University Hospital Giessen and Marburg GmbH, Location Marburg, Baldingerstraße, D-35043, Marburg, Germany.
T KnaufCenter for Orthopaedics and Trauma Surgery, University Hospital Giessen and Marburg GmbH, Location Marburg, Baldingerstraße, D-35043, Marburg, Germany.
A KönigDepartment of Diagnostic & Interventional Radiology, University Hospital Giessen and Marburg GmbH, Location Marburg, Marburg, Germany.
P LechlerCenter for Orthopaedics and Trauma Surgery, University Hospital Giessen and Marburg GmbH, Location Marburg, Baldingerstraße, D-35043, Marburg, Germany.
S RuchholtzCenter for Orthopaedics and Trauma Surgery, University Hospital Giessen and Marburg GmbH, Location Marburg, Baldingerstraße, D-35043, Marburg, Germany.
M FrinkCenter for Orthopaedics and Trauma Surgery, University Hospital Giessen and Marburg GmbH, Location Marburg, Baldingerstraße, D-35043, Marburg, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundWhile several studies report on accuracy rates of pedicle screws, risk factors associated with inaccurate pedicle screw positioning in patients with thoracolumbar fractures are reported rarely. CT scan as a routine postoperative control is advocated by various authors, however its necessity remains unclear.

methodsTwo hundred forty-five patients were included in this retrospective study. Percutaneous dorsal instrumentation was most commonly performed (n = 201). Classification of Zdichavsky et al. and Rao et al. were used to classify screw misplacement and anterior perforation was further evaluated according to the extent of perforation (< 2 mm; > 2 mm). Multivariate analysis was performed to identify risk factors for misplacement of screws.

resultsOne thousand sixty-eight pedicle screws were inserted in 245 patients. Misplacement was found in 51 screws (4.8%) in 42 patients (17.1%) according to the classification of Zdichavsky et al. and in 75 screws (7.0%) in 64 patients (26.1%) according to the classification of Rao et al.. An anterior perforation of the vertebral cortex was found in 56 screws (5.2%). Multivariate analysis showed fracture location in the upper thoracic (p = 0.048) and lumbar spine (p = 0.013) to be the only independent predictors for screw misplacement. In addition a significant correlation between pedicle diameter and the occurrence of screw malposition was found (p = 0.003). No consequences were drawn from postoperative routine CT in asymptomatic patients.

conclusionAn overall low rate of screw misplacement was found with fracture location in the upper thoracic and lumbar spine being the only factors independently associated with the risk of screw misplacement. No consequences were drawn from postoperative routine CT in asymptomatic patients. Therefore its use has to be discussed critically.

Indexed as

Pedicle ScrewsSpinal FusionHumansLumbar VertebraeRetrospective StudiesThoracic VertebraeTomography, X-Ray ComputedComputed tomographyRisk factorScrew misplacementThoracolumbar fracture

Identifiers

PMID34836522
PMCPMC8620926

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.