Evidence map›Paper›PMID 34834446›Full record

ArticleJournal of personalized medicine2021

A Replicable and Reproducible Digital Method for Quantifying Maxillary Sinus Airway Changes after Sinus Lifts Using the Lateral Window Approach Technique-A Retrospective Study.

Héctor González Menéndez, Paulina Rodríguez Torres, Blanca Muñoz Jiménez, Agustín Galparsoro Catalán, Pilar Velasco Bohórquez, Georgia Tzironi, Lara San Hipólito Marín, Álvaro Zubizarreta Macho, Sofía Hernández Montero

Open access · goldAbstract read
In one paragraph

Article in Journal of personalized medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.0field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Héctor González MenéndezDepartment of Implant Surgery, Faculty of Health Sciences, Alfonso X el Sabio University, 28691 Madrid, Spain.
Paulina Rodríguez TorresDepartment of Implant Surgery, Faculty of Health Sciences, Alfonso X el Sabio University, 28691 Madrid, Spain.
Blanca Muñoz JiménezDepartment of Implant Surgery, Faculty of Health Sciences, Alfonso X el Sabio University, 28691 Madrid, Spain.
Agustín Galparsoro CatalánDepartment of Implant Surgery, Faculty of Health Sciences, Alfonso X el Sabio University, 28691 Madrid, Spain.
Pilar Velasco BohórquezDepartment of Implant Surgery, Faculty of Health Sciences, Alfonso X el Sabio University, 28691 Madrid, Spain.
Georgia TzironiDepartment of Surgery, Faculty of Medicine, University of Salamanca, 37008 Salamanca, Spain.
Lara San Hipólito MarínDepartment of Implant Surgery, Faculty of Health Sciences, Alfonso X el Sabio University, 28691 Madrid, Spain.
Álvaro Zubizarreta MachoDepartment of Implant Surgery, Faculty of Health Sciences, Alfonso X el Sabio University, 28691 Madrid, Spain.
Sofía Hernández MonteroDepartment of Implant Surgery, Faculty of Health Sciences, Alfonso X el Sabio University, 28691 Madrid, Spain.
Universidad Alfonso X el Sabio · ESUniversidad de Salamanca · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In the present retrospective study, we aimed to assess the replicability and reproducibility of a novel digital measurement technique for analyzing the volumes of the left and right maxillary sinuses and the nasal and maxillary sinus airway complex after a sinus lift procedure using the lateral window approach, to provide an accurate measurement technique for easily applying in clinical practice and to allow pre-operative assessment of maxillary sinus lift surgery, avoiding complications and making surgery more predictable. MATERIAL AND

methodsThirty patients with partially edentulous posterior maxilla were selected and submitted to bilateral sinus lift using the lateral window approach technique, with grafting materials selected and submitted to cone beam computed tomography (CBCT) scans, both pre- and postoperatively. Then, datasets were uploaded to therapeutic digital planning software to measure the volume of the right and left maxillary sinuses and the nasal and maxillary sinus airway complex. Gage R&R statistical analysis was performed to assess the replicability and reproducibility of the digital measurement technique.

resultsThe variability attributable to the novel digital measurement technique was 3.4% for replicability and 3.4% for reproducibility of the total variability of the samples.

conclusionThe novel digital method proposed is a replicable and reproducible technique for analyzing the volume of the right and left maxillary sinuses and the nasal and maxillary sinus airway complex after a sinus lift using the lateral window approach technique, allowing an accurate pre-operative assessment of maxillary sinus lift surgery, avoiding complications and making surgery more predictable.

Indexed as

airway volumecone beam computed tomography scanlateral window approachmaxillary sinussinus lift

Identifiers

PMID34834446
PMCPMC8622529
OpenAlexW3209999858

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.