Evidence map›Paper›PMID 34833827›Full record

ArticleSensors (Basel, Switzerland)2021

Highly Discriminative Physiological Parameters for Thermal Pattern Classification.

Laura Benita Alvarado-Cruz, Carina Toxqui-Quitl, Raúl Castro-Ortega, Alfonso Padilla-Vivanco, José Humberto Arroyo-Núñez

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact, top 76% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Laura Benita Alvarado-CruzComputer Vision Laboratory, Universidad Politécnica de Tulancingo, Tulancingo de Bravo 43629, Mexico.ORCID 0000-0001-5565-1001
Carina Toxqui-QuitlComputer Vision Laboratory, Universidad Politécnica de Tulancingo, Tulancingo de Bravo 43629, Mexico.ORCID 0000-0003-1728-8138
Raúl Castro-OrtegaComputer Vision Laboratory, Universidad Politécnica de Tulancingo, Tulancingo de Bravo 43629, Mexico.ORCID 0000-0002-8416-2271
Alfonso Padilla-VivancoComputer Vision Laboratory, Universidad Politécnica de Tulancingo, Tulancingo de Bravo 43629, Mexico.ORCID 0000-0002-9702-1013
José Humberto Arroyo-NúñezComputer Vision Laboratory, Universidad Politécnica de Tulancingo, Tulancingo de Bravo 43629, Mexico.ORCID 0000-0003-2459-8783
Universidad Politécnica de Tulancingo · MX

Funding

Consejo Nacional de Ciencia y Tecnología 786815
6 · The paper itself

Abstract

Infrared Thermography (IRT) is a non-contact, non-intrusive, and non-ionizing radiation tool used for detecting breast lesions. This paper analyzes the surface temperature distribution (STD) on an optimal Region of Interest (RoI) for extraction of suitable internal heat source parameters. The physiological parameters are estimated through the inverse solution of the bio-heat equation and the STD of suspicious areas related to the hottest spots of the RoI. To reach these values, the STD is analyzed by means: the Depth-Intensity-Radius (D-I-R) measurement model and the fitting method of Lorentz curve. A highly discriminative pattern vector composed of the extracted physiological parameters is proposed to classify normal and abnormal breast thermograms. A well-defined RoI is delimited at a radial distance, determined by the Support Vector Machines (SVM). Nevertheless, this distance is less than or equal to 1.8 cm due to the maximum temperature location close to the boundary image. The methodology is applied to 87 breast thermograms that belong to the Database for Mastology Research with Infrared Image (DMR-IR). This methodology does not apply any image enhancements or normalization of input data. At an optimal position, the three-dimensional scattergrams show a correct separation between normal and abnormal thermograms. In other cases, the feature vectors are highly correlated. According to our experimental results, the proposed pattern vector extracted at optimal position a=1.6 cm reaches the highest sensitivity, specificity, and accuracy. Even more, the proposed technique utilizes a reduced number of physiological parameters to obtain a Correct Rate Classification (CRC) of 100%. The precision assessment confirms the performance superiority of the proposed method compared with other techniques for the breast thermogram classification of the DMR-IR.

Indexed as

Breast NeoplasmsThermographyFemaleHot TemperatureHumansImage EnhancementSupport Vector MachineTemperaturebreast thermographyD-I-R modelfeature extractionheat source parametersinfrared imaging

Identifiers

PMID34833827
PMCPMC8618047
OpenAlexW3216705549

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.