Evidence map›Paper›PMID 34833708›Full record

ArticleSensors (Basel, Switzerland)2021

Simply Fabricated Inexpensive Dual-Polymer-Coated Fabry-Perot Interferometer-Based Temperature Sensors with High Sensitivity.

Tejaswi Tanaji Salunkhe, Ho Kyung Lee, Hyung Wook Choi, Sang Joon Park, Il Tae Kim

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.4field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Tejaswi Tanaji SalunkheDepartment of Chemical and Biological Engineering, Gachon University, Seongnam-si 13120, Korea.ORCID 0000-0001-8743-9515
Ho Kyung LeeDepartment of Chemical and Biological Engineering, Gachon University, Seongnam-si 13120, Korea.
Hyung Wook ChoiDepartment of Electrical Engineering, Gachon University, Seongnam-si 13120, Korea.
Sang Joon ParkDepartment of Chemical and Biological Engineering, Gachon University, Seongnam-si 13120, Korea.
Il Tae KimDepartment of Chemical and Biological Engineering, Gachon University, Seongnam-si 13120, Korea.ORCID 0000-0002-8857-0061
Gachon University · KR

Funding

Gachon University GCU-2019-0806Korea Institute of Energy Technology Evaluation and Planning 20194030202290
6 · The paper itself

Abstract

We designed simply fabricated, highly sensitive, and cost-effective dual-polymer-coated Fabry-Perot interferometer (DFPI)-based temperature sensors by employing thermosensitive polymers and non-thermosensitive polymers, as well as different two successive dip-coating techniques (stepwise dip coating and polymer mixture coating). Seven sensors were fabricated using different polymer combinations for performance optimization. The experiments demonstrated that the stepwise dip-coated dual thermosensitive polymer sensors exhibited the highest sensitivity (2142.5 pm °C

Indexed as

PolymersPolymethyl MethacrylatePolystyrenesReproducibility of ResultsTemperaturePolymersPolymethyl MethacrylatePolystyrenesdual-polymer-coated sensorFabry–Perot interferometerhigh sensitivitythermosensitive polymer

Identifiers

PMID34833708
PMCPMC8620928
OpenAlexW3214407593

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.