Evidence map›Paper›PMID 34833678›Full record

ArticleSensors (Basel, Switzerland)2021

Modeling and Parallel Operation of Exchange-Biased Delta-E Effect Magnetometers for Sensor Arrays.

Benjamin Spetzler, Patrick Wiegand, Phillip Durdaut, Michael Höft, Andreas Bahr, Robert Rieger, Franz Faupel

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Benjamin SpetzlerInstitute of Materials Science, Faculty of Engineering, Kiel University, 24143 Kiel, Germany.ORCID 0000-0003-4255-5947
Patrick WiegandInstitute of Materials Science, Faculty of Engineering, Kiel University, 24143 Kiel, Germany.
Phillip DurdautInstitute of Materials Science, Faculty of Engineering, Kiel University, 24143 Kiel, Germany.ORCID 0000-0001-9839-3890
Michael HöftInstitute of Materials Science, Faculty of Engineering, Kiel University, 24143 Kiel, Germany.ORCID 0000-0001-9352-2868
Andreas BahrInstitute of Materials Science, Faculty of Engineering, Kiel University, 24143 Kiel, Germany.ORCID 0000-0001-8012-6794
Robert RiegerInstitute of Materials Science, Faculty of Engineering, Kiel University, 24143 Kiel, Germany.ORCID 0000-0002-4436-0804
Franz FaupelInstitute of Materials Science, Faculty of Engineering, Kiel University, 24143 Kiel, Germany.ORCID 0000-0003-3367-1655

Funding

Deutsche Forschungsgemeinschaft CRC1261
6 · The paper itself

Abstract

Recently, Delta-E effect magnetic field sensors based on exchange-biased magnetic multilayers have shown the potential of detecting low-frequency and small-amplitude magnetic fields. Their design is compatible with microelectromechanical system technology, potentially small, and therefore, suitable for arrays with a large number N of sensor elements. In this study, we explore the prospects and limitations for improving the detection limit by averaging the output of N sensor elements operated in parallel with a single oscillator and a single amplifier to avoid additional electronics and keep the setup compact. Measurements are performed on a two-element array of exchange-biased sensor elements to validate a signal and noise model. With the model, we estimate requirements and tolerances for sensor elements using larger N. It is found that the intrinsic noise of the sensor elements can be considered uncorrelated, and the signal amplitude is improved if the resonance frequencies differ by less than approximately half the bandwidth of the resonators. Under these conditions, the averaging results in a maximum improvement in the detection limit by a factor of N. A maximum N≈200 exists, which depends on the read-out electronics and the sensor intrinsic noise. Overall, the results indicate that significant improvement in the limit of detection is possible, and a model is presented for optimizing the design of delta-E effect sensor arrays in the future.

Indexed as

cantileverdelta-E effectexchange biasmagnetoelectricmagnetometersensor array

Identifiers

PMID34833678
PMCPMC8619412

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390