Evidence map›Paper›PMID 34832695›Full record

ArticleMicromachines2021

A Microfluidic Aptamer-Based Sensor for Detection of Mercury(II) and Lead(II) Ions in Water.

Wei-Hao Huang, Van-Phung Mai, Ruo-Yin Wu, Ko-Li Yeh, Ruey-Jen Yang

Abstract read
In one paragraph

Article in Micromachines, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Review
  2. Review
  3. Review
  4. Sensing lead ions in water: a comprehensive review on strategies and sensor materials.Analytical sciences : the international journal of the Japan Society for Analytical Chemistry · 2024
    Review
  5. Review
  6. Review
  7. Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Wei-Hao HuangDepartment of Engineering Science, National Cheng Kung University, Tainan 70101, Taiwan.ORCID 0000-0002-8037-7208
Van-Phung MaiDepartment of Engineering Science, National Cheng Kung University, Tainan 70101, Taiwan.ORCID 0000-0002-5756-0274
Ruo-Yin WuDepartment of Engineering Science, National Cheng Kung University, Tainan 70101, Taiwan.
Ko-Li YehDepartment of Engineering Science, National Cheng Kung University, Tainan 70101, Taiwan.
Ruey-Jen YangDepartment of Engineering Science, National Cheng Kung University, Tainan 70101, Taiwan.ORCID 0000-0002-1958-0389

Funding

Ministry of Science and Technology MOST- 107-2221-E-006-127-MY3
6 · The paper itself

Abstract

Heavy metal contaminants have serious consequences for the environment and human health. Consequently, effective methods for detecting their presence, particularly in water and food, are urgently required. Accordingly, the present study proposes a sensor capable of detecting mercury Hg(II) and lead Pb(II) ions simultaneously, using graphene oxide (GO) as a quenching agent and an aptamer solution as a reagent. In the proposed device, the aptamer sequences are labeled by FAM and HEX fluorescent dyes, respectively, and are mixed well with 500 ppm GO solution before injection into one inlet of the microchannel, and the heavy metal sample solution is injected into another inlet. The presence of Hg(II) and Pb(II) ions is then detected by measuring the change in the fluorescence intensity of the GO/aptamer suspension as the aptamer molecules undergo fluorescence resonance energy transfer (FRET). The selectivity of these two ions is also shown to be clear among other mixed heavy metal ions. The experimental results show that the aptamer sensors have a linear range of 10~250 nM (i.e., 2.0~50 ppb) for Hg(II) ions and 10~100 nM (i.e., 2.1~20.7 ppb) for Pb(II) ions. Furthermore, the limit of detection is around 0.70 ppb and 0.53 ppb for Hg(II) and Pb(II), respectively, which is lower than the maximum limits of 6 ppb and 10 ppb prescribed by the World Health Organization (WHO) for Hg(II) and Pb(II) in drinking water, respectively.

Indexed as

aptamerfluorescence resonance energy transfergraphene oxideheavy metal ionsmicrofluidic devicesensor

Identifiers

PMID34832695
PMCPMC8619161

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.