ArticleCancers2021
Accuracy and Safety of Ultrasound-Guided Core Needle Biopsy of Soft Tissue Tumors in an Outpatient Setting: A Sarcoma Center Analysis of 392 Consecutive Patients.
Article in Cancers, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 1 synthesis or guideline pooled it, 18 citations in OpenAlex.
- ISUOG/ESGO Consensus Statement on ultrasound-guided biopsy in gynecological oncology.Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology · 2025Guideline
- Long-term outcomes of a phase II study of neoadjuvant imatinib in large gastrointestinal stromal tumors of the stomach.Gastric cancer : official journal of the International Gastric Cancer Association and the Japanese Gastric Cancer Association · 2023Trial
- Core Needle Biopsies in Patients With Lymphoproliferative Malignancies: An Observational Single-Center Cohort Study.European journal of haematology · 2026Observational
- ASO Practice Guidelines Series: Soft Tissue Sarcoma of the Extremities and Superficial Trunk.Annals of surgical oncology · 2025Review
- Research on application of multiparametric MRI to predict FNCLCC grading and ki67 expression in soft tissue sarcoma biopsy pathology: Based on a CT-MRI fusion image registration method.Frontiers in oncology · 2025Article
- Analysis on diagnostic failure of US-guided core needle biopsy for soft tissue tumors.Research in diagnostic and interventional imaging · 2023Article
- Article
- Article
- A Novel Biopsy Method Based on Bipolar Radiofrequency Biopsy Needles.Frontiers in oncology · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe aim of this study was to investigate diagnostic accuracy, safety and histologic results of ultrasound guided core needle biopsy (CNB) in patients with soft tissue lesions (STL) at a tertiary referral center.
methodsA retrospective analysis of all consecutive patients undergoing ultrasound guided CNB for STL at our sarcoma outpatient service between January 2015 and August 2020 was performed.
resultsA total of 392 patients were identified. Main histologic entities were sarcomas, lipomas and desmoid tumors. Biopsy was performed in an outpatient setting in 87.6% of the cases. Conclusive biopsies were obtained in 88.5% of the cases. In patients who underwent surgical resection after CNB, the concordance of dignity, tumor entity and histopathological grading between biopsy and resection specimen were 97.2%, 92.7% and 92.5% respectively. The risk of inconclusive CNB was highest in intraabdominal or retroperitoneal tumors (19.5%) and lowest in lesions at the lower extremity (4.4%). Major complications after CNB occurred in three cases (0.8%). No case of biopsy tract seeding was observed during the study period.
conclusionsUltrasound guided CNB for STL at first presentation in a dedicated surgical outpatient setting is a safe procedure and yields a high diagnostic accuracy.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.