Evidence map›Paper›PMID 34829897›Full record

ArticleBiomedicines2021

An Additively Manufactured Sample Holder to Measure the Controlled Release of Vancomycin from Collagen Laminates.

Michelle Fiona Kilb, Yannik Moos, Stefanie Eckes, Joy Braun, Ulrike Ritz, Daniela Nickel, Katja Schmitz

Abstract read
In one paragraph

Article in Biomedicines, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Michelle Fiona KilbClemens-Schöpf-Institute of Organic Chemistry and Biochemistry, Technical University of Darmstadt, Alarich-Weiss-Straße 8, 64287 Darmstadt, Germany.ORCID 0000-0002-4871-6687
Yannik MoosAkademische Motorsportgruppe Darmstadt e.V., c/o Institut für Verbrennungskraftmaschinen und Fahrzeugantriebe, Otto-Berndt-Straße 2, 64287 Darmstadt, Germany.
Stefanie EckesClemens-Schöpf-Institute of Organic Chemistry and Biochemistry, Technical University of Darmstadt, Alarich-Weiss-Straße 8, 64287 Darmstadt, Germany.ORCID 0000-0001-7583-7508
Joy BraunDepartment of Orthopaedics and Traumatology, BiomaTiCS, University Medical Center, Johannes Gutenberg University, Langenbeckstraße 1, 55131 Mainz, Germany.ORCID 0000-0002-7500-6875
Ulrike RitzDepartment of Orthopaedics and Traumatology, BiomaTiCS, University Medical Center, Johannes Gutenberg University, Langenbeckstraße 1, 55131 Mainz, Germany.ORCID 0000-0001-8936-3227
Daniela NickelBerufsakademie Sachsen-Staatliche Studienakademie Glauchau, University of Cooperative Education, Kopernikusstraße 51, 08371 Glauchau, Germany.
Katja SchmitzClemens-Schöpf-Institute of Organic Chemistry and Biochemistry, Technical University of Darmstadt, Alarich-Weiss-Straße 8, 64287 Darmstadt, Germany.ORCID 0000-0001-9023-318X

Funding

Deutsche Forschungsgemeinschaft 400569699
6 · The paper itself

Abstract

The controlled release of antibiotics prevents the spread of pathogens and thereby improves healing processes in regenerative medicine. However, high concentrations may interfere with healing processes. It is therefore advantageous to use biodegradable materials for a controlled release. In particular, multilayer materials enable differential release at different surfaces. For this purpose, collagen sheets of different properties can be bonded by photochemical crosslinking. Here, we present the development and application of an easily accessible, additively manufactured sample holder to study the controlled release of vancomycin from modularly assembled collagen laminates in two directions. As proof-of-concept, we show that laminates of collagen sheets covalently linked by rose bengal and green light crosslinking (RGX) can be tightly inserted into the device without leakage from the upper to lower cavity. We used this sample holder to detect the release of vancomycin from symmetrically and asymmetrically loaded two-layer and three-layer collagen laminates into the upper and lower cavity of the sample holder. We show that these collagen laminates are characterized by a collagen type-dependent vancomycin release, enabling the control of antibiotic release profiles as well as the direction of antibiotic release.

Indexed as

additively manufactured sample holdercollagencontrolled releasecrosslinkingvancomycin

Identifiers

PMID34829897
PMCPMC8615449

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.