Evidence map›Paper›PMID 34829482›Full record

ArticleDiagnostics (Basel, Switzerland)2021

Quantitative Magnetic Resonance Imaging in Perianal Crohn's Disease at 1.5 and 3.0 T: A Feasibility Study.

Ali Alyami, Caroline L Hoad, Christopher Tench, Uday Bannur, Christopher Clarke, Khalid Latief, Konstantinos Argyriou, Alan Lobo, Philip Lung, Rachel Baldwin-Cleland and 10 more

Open access · goldAbstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.8field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 9 citations in OpenAlex.

  1. Clinical Trial Endpoints for Perianal Fistulizing Crohn's Disease.The American journal of gastroenterology · 2026
    Review
  2. Article
  3. Review
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

20 authors at 8 institutions in 2 countries.

Ali AlyamiDepartment of Diagnostic Radiography Technology, College of Applied Medical Sciences, Jazan University, Jazan 45142, Saudi Arabia.
Caroline L HoadNational Institute of Health Research Nottingham Biomedical Research Centre at the Nottingham University Hospitals NHS Trust and University of Nottingham, Nottingham NG7 2UH, UK.ORCID 0000-0001-5483-1027
Christopher TenchNational Institute of Health Research Nottingham Biomedical Research Centre at the Nottingham University Hospitals NHS Trust and University of Nottingham, Nottingham NG7 2UH, UK.
Uday BannurDepartment of Radiology, Queens Medical Centre Campus, Nottingham University Hospitals, Nottingham NG7 2UH, UK.
Christopher ClarkeDepartment of Radiology, Queens Medical Centre Campus, Nottingham University Hospitals, Nottingham NG7 2UH, UK.ORCID 0000-0002-8092-9877
Khalid LatiefDepartment of Radiology, Queens Medical Centre Campus, Nottingham University Hospitals, Nottingham NG7 2UH, UK.
Konstantinos ArgyriouTranslational Medical Sciences Academic Unit, School of Medicine, Faculty of Medicine and Health Sciences, University of Nottingham, Nottingham NG7 2UH, UK.ORCID 0000-0002-2026-9678
Alan LoboDepartment of Gastroenterology, Sheffield Teaching Hospitals NHS Trust, Sheffield S10 2JF, UK.
Philip LungDepartment of Radiology, St Mark's Hospital and Academic Institute, London North West Healthcare NHS Trust, London HA1 3UJ, UK.
Rachel Baldwin-ClelandDepartment of Radiology, St Mark's Hospital and Academic Institute, London North West Healthcare NHS Trust, London HA1 3UJ, UK.
Kapil SahnanFistula Research Unit, St Mark's Hospital and Academic Institute, London North West Healthcare NHS Trust, London HA1 3UJ, UK.
Ailsa HartFistula Research Unit, St Mark's Hospital and Academic Institute, London North West Healthcare NHS Trust, London HA1 3UJ, UK.
Jimmy K LimdiDepartment of Gastroenterology, The Pennine Acute Hospitals NHS Trust, Greater Manchester, Crumpsall M8 5RB, UK.
John MclaughlinDepartment of Gastroenterology, Salford Royal NHS Foundation Trust, Manchester Academic Health Sciences Centre, Salford M6 8HD, UK.ORCID 0000-0001-6158-5135
David AtkinsonCentre for Medical Imaging, University College London, London W1W 7TS, UK.ORCID 0000-0003-1124-6666
Geoffrey J M ParkerCentre for Medical Image Computing, Department of Medical Physics and Biomedical Engineering, University College London, London WC1V 6LJ, UK.ORCID 0000-0003-2934-2234
James P B O'ConnorQuantitative Biomedical Imaging Laboratory, Division of Cancer Science, University of Manchester, Manchester M13 9PL, UK.
Ross A LittleQuantitative Biomedical Imaging Laboratory, Division of Cancer Science, University of Manchester, Manchester M13 9PL, UK.
Penny A GowlandNational Institute of Health Research Nottingham Biomedical Research Centre at the Nottingham University Hospitals NHS Trust and University of Nottingham, Nottingham NG7 2UH, UK.ORCID 0000-0002-4900-4817
Gordon W MoranTranslational Medical Sciences Academic Unit, School of Medicine, Faculty of Medicine and Health Sciences, University of Nottingham, Nottingham NG7 2UH, UK.ORCID 0000-0002-8906-6908
Nottingham University Hospitals NHS Trust · GBLondon North West Healthcare NHS Trust · GBUniversity College London · GBUniversity of Manchester · GBPennine Acute Hospitals NHS Trust · GBSalford Royal NHS Foundation Trust · GBSheffield Teaching Hospitals NHS Foundation Trust · GBUniversity of Nottingham · GB

Funding

Medical Research Council MC_PC_15033
6 · The paper itself

Abstract

Perianal Crohn's Disease (pCD) is a common manifestation of Crohn's Disease. Absence of reliable disease measures makes disease monitoring unreliable. Qualitative MRI has been increasingly used for diagnosing and monitoring pCD and has shown potential for assessing response to treatment. Quantitative MRI sequences, such as diffusion-weighted imaging (DWI), dynamic contrast enhancement (DCE) and magnetisation transfer (MT), along with T2 relaxometry, offer opportunities to improve diagnostic capability. Quantitative MRI sequences (DWI, DCE, MT and T2) were used in a cohort of 25 pCD patients before and 12 weeks after biological therapy at two different field strengths (1.5 and 3 T). Disease activity was measured with the Perianal Crohn's Disease Activity index (PDAI) and serum C-reactive protein (CRP). Diseased tissue areas on MRI were defined by a radiologist. A baseline model to predict outcome at 12 weeks was developed. No differences were seen in the quantitative MR measured in the diseased tissue regions from baseline to 12 weeks; however, PDAI and CRP decreased. Baseline PDAI, CRP, T2 relaxometry and surgical history were found to have a moderate ability to predict response after 12 weeks of biological treatment. Validation in larger cohorts with MRI and clinical measures are needed in order to further develop the model.

Indexed as

DCEDWIMTperianal Crohn’s diseasequantitative MRIT2

Identifiers

PMID34829482
PMCPMC8624877
OpenAlexW3214377554

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.