ArticleFoods (Basel, Switzerland)2021
Establishment and Validation of a GC-MS/MS Method for the Quantification of Penicillin G Residues in Poultry Eggs.
Article in Foods (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Quantitative Analysis of Decoquinate Residues in Hen Eggs through Derivatization-Gas Chromatography Tandem Mass Spectrometry.Foods (Basel, Switzerland) · 2023Article
- [Determination of three penicillin residues in milk by solid-phase extraction-ultra performance liquid chromatography-tandem mass spectrometry using a covalent triazine framework sorbent].Se pu = Chinese journal of chromatography · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
A simple and sensitive gas chromatography-tandem mass spectrometry (GC-MS/MS) method was established for the quantitative screening of penicillin G residues in chicken and duck eggs (whole egg, yolk and albumen). The analyte was separated on a TG-1MS capillary column (30.0 m × 0.25 mm i.d., 0.25 μm) with an external calibration method and electron impact (EI) ionization. Samples were pretreated using an accelerated solvent extraction (ASE) procedure followed by solid-phase extraction (SPE) on HLB cartridges (60 mg/3 mL). The derivative, which was safer and easier to store than penicillin G, was obtained by reacting trimethylsilyl diazomethane (TMSD) with penicillin G. The method was validated by the following parameters: linearity, accuracy, precision, limit of detection (LOD) and limit of quantification (LOQ). The matrix-matched calibration curves had good linearity (R2 ≥ 0.9994) within the concentration range of LOQ-200.0 µg/kg for penicillin G in the sample matrices. In the same concentration range, the accuracy, in terms of recovery, was 80.31-94.50%; the relative standard deviation (RSD), intra-day RSD and inter-day RSD ranged from 1.24 to 3.44%, 2.13 to 4.82% and 2.74 to 6.13%, respectively. The LODs and LOQs of penicillin G in the matrices were in the ranges of 1.70-3.20 and 6.10-8.50 μg/kg, respectively. The applicability of the GC-MS/MS method was demonstrated by the determination of poultry eggs obtained from local markets with no penicillin G residues.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.