ArticleHealthcare (Basel, Switzerland)2021
Infection Control Improvement of a Negative-Pressurized Pediatric Intensive Care Unit.
Article in Healthcare (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 6 citations in OpenAlex.
- Article
- Ventilation Performance Evaluation of a Negative-Pressurized Isolation Room for Emergency Departments.Healthcare (Basel, Switzerland) · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 2 countries.
Funding
Abstract
The COVID-19 pandemic caused by the novel SARS-CoV-2 virus raises alarming concern around the healthcare facilities due to the significant increase in patient inflow. Negative-pressurized isolation rooms have been utilized in various health care facilities to isolate the patients from active community contact. Several studies have highlighted isolation rooms improvement. However, limited knowledge is available regarding the isolation room facilities for pediatric intensive care units (PICU) to accommodate more than one pediatric patient. In this aspect, this study investigates a negative-pressurized isolation facility in PICU with minimal design modifications with the possibility that it can accommodate more than one pediatric patient. The field measurement tests were conducted to ensure the design compliance of Taiwan CDC. Then, computational fluid dynamics (CFD) was further utilized to numerically evaluate the HVAC system role and the ventilation performance towards infection control. A protected air-jet curtain system with a new ventilation layout was proposed through this study to enhance the protection for both pediatric patients and medical staff. The concentration decay was monitored and recorded within 900 s to evaluate the performance. The concentration can be reduced to 504 ppm for case 1, 620 ppm for case 2, 501 ppm for case 3, and 486 ppm for case 4. In addition, the injected bioaerosol particles could be well diluted dealing with two patients presents a good performance. The results revealed that this proposed configuration could feasibly accommodate two patients with a significant contamination control to protect the medical staff and patients.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.