ArticleArchives of orthopaedic and trauma surgery2022
Radiologic restoration inaccuracy increases postoperative dislocation in primary total hip arthroplasty: a retrospective study with propensity score matching.
Article in Archives of orthopaedic and trauma surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 1 synthesis or guideline pooled it, 4 citations in OpenAlex.
- Did the dislocation risk after primary total hip arthroplasty decrease over time? A meta-analysis across six decades.Archives of orthopaedic and trauma surgery · 2023Pooled it
- Postoperative longer leg on surgical side and high riding greater trochanter worsen forgotten joint score after unilateral total hip arthroplasty.Scientific reports · 2025Article
- Radiological factors associated with posterior dislocation after total hip arthroplasty for osteonecrosis of the femoral head - A retrospective study.Journal of orthopaedics · 2024Article
- The posterior tibial slope and Insall-Salvati index in operative and nonoperative adolescent athletes with Osgood-Schlatter disease.Archives of orthopaedic and trauma surgery · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
Abstract
backgroundDislocation is a complicated process and associated with multivariate etiology and risk factors. The purpose of this study was to verify if radiologic restoration inaccuracy increases postoperative dislocation in primary total hip arthroplasty (THA) individually or synergistically.
methodsFrom 2017 to 2020, we identified 76 (1.9%) patients who suffered postoperative dislocations from 3926 THAs in our institution. After excluded patients with previously proven patient-related and implant-related risk factors, the remaining patients were used to match a 1:1 control patients who were without dislocation. The cup position (inclination and anteversion angles), hip offset (HO), leg length discrepancy (LLD), and abductor lever arm (ALA) were analyzed by univariate analyses and multivariate logistic regressions.
resultsMeasurements on radiographs showed excellent interobserver agreement (intraclass correlation coefficient (ICC) 0.922-0.952) and intraobserver agreements (ICC 0.933-0.967). HO restoration inaccuracy (without ± 5 mm) was associated with higher dislocation risk (OR 4.241 95% CI 1.440-12.492, P = 0.009). The restoration inaccuracy of the cup position, LLD, or ALA could not increase the dislocation risk individually. When combining the radiologic restoration inaccuracy factors, the HO + LLD restoration inaccuracy and HO + ALA restoration inaccuracy increased the odds of postoperative dislocation (OR 12.056, 95% CI 1.409-103.127, P = 0.023; OR 4.770, 95% CI 1.336-17.028, P = 0.016, respectively). Combining the four risk factors of cup safe zone, HO, LLD, and ALA, patients with 3 or 4 radiologic restoration inaccuracy factors showed a higher risk of dislocation (OR 13.500, 95% CI 1.340-135.983, P = 0.027).
conclusionHip offset (HO) restoration inaccuracy increased the risk of dislocation following primary THA. Multivariate radiologic restoration accuracy is critical for the prevention of dislocation and needs to be valued by surgeons.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials