Evidence map›Paper›PMID 34821651›Full record

ArticleBiosensors2021

High Channel Temperature Mapping Electronics in a Thin, Soft, Wireless Format for Non-Invasive Body Thermal Analysis.

Wooyoung Park, Chunki Yiu, Yiming Liu, Tsz Hung Wong, Xingcan Huang, Jingkun Zhou, Jian Li, Kuanming Yao, Ya Huang, Hu Li and 4 more

Open access · goldAbstract read
In one paragraph

Article in Biosensors, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.5field-weighted citation impact, top 39% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Review
  3. [Application of electronic skin in healthcare and virtual reality].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors at 1 institution in 1 country.

Wooyoung ParkDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong 999077, China.ORCID 0000-0003-2250-3613
Chunki YiuDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong 999077, China.ORCID 0000-0003-3841-5327
Yiming LiuDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong 999077, China.
Tsz Hung WongDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong 999077, China.
Xingcan HuangDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong 999077, China.
Jingkun ZhouDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong 999077, China.
Jian LiDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong 999077, China.
Kuanming YaoDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong 999077, China.
Ya HuangDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong 999077, China.
Hu LiDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong 999077, China.
Jiyu LiDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong 999077, China.
Yanli JiaoDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong 999077, China.
Rui ShiDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong 999077, China.
Xinge YuDepartment of Biomedical Engineering, City University of Hong Kong, Hong Kong 999077, China.ORCID 0000-0003-0522-1171
City University of Hong Kong · HK

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Hemodynamic status has been perceived as an important diagnostic value as fundamental physiological health conditions, including decisive signs of fatal diseases like arteriosclerosis, can be diagnosed by monitoring it. Currently, the conventional hemodynamic monitoring methods highly rely on imaging techniques requiring inconveniently large numbers of operation procedures and equipment for mapping and with a high risk of radiation exposure. Herein, an ultra-thin, noninvasive, and flexible electronic skin (e-skin) hemodynamic monitoring system based on the thermal properties of blood vessels underneath the epidermis that can be portably attached to the skin for operation is introduced. Through a series of thermal sensors, the temperatures of each subsection of the arrayed sensors are observed in real-time, and the measurements are transmitted and displayed on the screen of an external device wirelessly through a Bluetooth module using a graphical user interface (GUI). The degrees of the thermal property of subsections are indicated with a spectrum of colors that specify the hemodynamic status of the target vessel. In addition, as the sensors are installed on a soft substrate, they can operate under twisting and bending without any malfunction. These characteristics of e-skin sensors exhibit great potential in wearable and portable diagnostics including point-of-care (POC) devices.

Indexed as

ThermographyWearable Electronic DevicesWireless TechnologyHumansMonitoring, PhysiologicSkinflexible electronicshuman temperature measuringskin-like electronicsthermistorwireless communication

Identifiers

PMID34821651
PMCPMC8615861
OpenAlexW3211209834

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.