Evidence map›Paper›PMID 34819717›Full record

ArticleClinical ophthalmology (Auckland, N.Z.)2021

Steady-State Pattern Electroretinography in Eyes with Glaucoma and High Myopia.

Xian Hui Lim, Monisha Esther Nongpiur, Raymond P Najjar, Quan V Hoang, Dan Milea, Chee Wai Wong, Rahat Husain, Hla Myint Htoon, Tin Aung, Shamira Perera and 1 more

Open access · goldAbstract read
In one paragraph

Article in Clinical ophthalmology (Auckland, N.Z.), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.7field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 4 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 3 institutions in 2 countries.

Xian Hui LimSingapore National Eye Centre, Singapore.
Monisha Esther NongpiurSingapore National Eye Centre, Singapore.
Raymond P NajjarSingapore Eye Research Institute, Singapore.ORCID 0000-0002-3770-2300
Quan V HoangSingapore National Eye Centre, Singapore.
Dan MileaSingapore National Eye Centre, Singapore.
Chee Wai WongSingapore National Eye Centre, Singapore.
Rahat HusainSingapore National Eye Centre, Singapore.
Hla Myint HtoonSingapore Eye Research Institute, Singapore.
Tin AungSingapore National Eye Centre, Singapore.
Shamira PereraSingapore National Eye Centre, Singapore.
Tina Tzee Ling WongSingapore National Eye Centre, Singapore.
Singapore National Eye Center · SGNational University of Singapore · SGSingapore Eye Research Institute · SG

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo investigate features of the steady-state pattern electroretinogram (ssPERG) in subjects with glaucoma (G), high myopia (HM; spherical equivalent ≤-6D) and glaucoma with high myopia (GHM). PATIENTS AND

methodsOur study included 48 participants divided into 3 groups (G, HM, and GHM) who each underwent monocular ssPERG testing with Diopsys NOVA PERG protocols. The ConStim protocol detects distinct topographic patterns of dysfunction 16° and 24° around the central macula. MagD is the amplitude of the average signal and MagD/Mag ratio indicates the consistency of the response. ssPERG indices were compared between groups and correlated with functional (ie, visual field mean deviation (VFMD)) and structural (ie, average retinal nerve fibre layer (RNFL) thickness; Cirrus optical coherence tomography) features.

resultsParticipants had an average age of 59.4±7.6 years. Mean Humphrey VFMD was -14.22 ± 2.88dB, -2.62 ± 1.18dB and -12.80 ± 2.60dB for G, HM and GHM groups, respectively. Mean RNFL thickness was 63.0 ± 8.20μm, 69.5 ± 15.7μm and 60.6 ± 5.0μm for G, HM and GHM groups, respectively. For the 24° setting, no significant differences were noted for any of the parameters. For the 16° setting, MagD was lower in the GHM group compared to the HM group (0.29µV vs 0.52µV; p = 0.02). Significant differences were noted for the MagD/Mag ratio between HM and G groups (0.58 vs 0.40; p = 0.02) and between HM and GHM groups (0.58 vs 0.35; p = 0.002). There were positive correlations between both MagD 16° and MagD/Mag ratio 16° with VFMD (correlation coefficient [r]=0.37, p = 0.009; and r = 0.44, p = 0.002, respectively) and RNFL (r = 0.43, p = 0.002; and r = 0.48, p = 0.001, respectively).

conclusionMagD/Mag ratio at 16° was significantly lower in glaucomatous eyes (with or without high myopia) compared to those with high myopia without glaucoma, suggesting that glaucoma has a distinct impact on MagD/Mag ratio at 16° irrespective of the presence of myopia.

Indexed as

optical coherence tomographypattern electroretinogramretinal nerve fibre layervisual field mean deviation

Identifiers

PMID34819717
PMCPMC8607345
OpenAlexW3213834950

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.