Evidence map›Paper›PMID 34815501›Full record

ArticleScientific reports2021

Feasibility study of portable multi-energy computed tomography with photon-counting detector for preclinical and clinical applications.

Chang-Lae Lee, Key Jo Hong, Namwoo Kim, Kwanhee Han, Dongkyu Kim, Hoe-Su Jung, Sangmin Lee, Junyoung Park, Kyoung-Yong Lee, Jee Eun Lee and 2 more

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.4field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Review
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 2 institutions in 1 country.

Chang-Lae LeePCD R&D Group, Health & Medical Equipment Business Unit, Samsung Electronics, Suwon-si, Gyeonggido, Korea.
Key Jo HongPCD R&D Group, Health & Medical Equipment Business Unit, Samsung Electronics, Suwon-si, Gyeonggido, Korea.
Namwoo KimPCD R&D Group, Health & Medical Equipment Business Unit, Samsung Electronics, Suwon-si, Gyeonggido, Korea.
Kwanhee HanPCD R&D Group, Health & Medical Equipment Business Unit, Samsung Electronics, Suwon-si, Gyeonggido, Korea.
Dongkyu KimLaboratory Animal Center, Daegu Gyeongbuk Medical Innovation Foundation, Daegu, Korea.
Hoe-Su JungLaboratory Animal Center, Daegu Gyeongbuk Medical Innovation Foundation, Daegu, Korea.
Sangmin LeePCD R&D Group, Health & Medical Equipment Business Unit, Samsung Electronics, Suwon-si, Gyeonggido, Korea.
Junyoung ParkPCD R&D Group, Health & Medical Equipment Business Unit, Samsung Electronics, Suwon-si, Gyeonggido, Korea.
Kyoung-Yong LeePCD R&D Group, Health & Medical Equipment Business Unit, Samsung Electronics, Suwon-si, Gyeonggido, Korea.
Jee Eun LeeDepartment of Family Medicine, Bupyeong Serim Hospital, Incheon, Korea.
Yuna ChoiPCD R&D Group, Health & Medical Equipment Business Unit, Samsung Electronics, Suwon-si, Gyeonggido, Korea. yuna.choi@samsung.com.
Minkook ChoPCD R&D Group, Health & Medical Equipment Business Unit, Samsung Electronics, Suwon-si, Gyeonggido, Korea. minkook.cho@samsung.com.
Samsung (South Korea) · KRDaegu-Gyeongbuk Medical Innovation Foundation · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In this study, preclinical experiments were performed with an in-house developed prototypal photon-counting detector computed tomography (PCD CT) system. The performance of the system was compared with the conventional energy-integrating detector (EID)-based CT, concerning the basic image quality biomarkers and the respective capacities for material separation. The pre- and the post-contrast axial images of a canine brain captured by the PCD CT and EID CT systems were found to be visually similar. Multi-energy images were acquired using the PCD CT system, and machine learning-based material decomposition was performed to segment the white and gray matters for the first time in soft tissue segmentation. Furthermore, to accommodate clinical applications that require high resolution acquisitions, a small, native, high-resolution (HR) detector was implemented on the PCD CT system, and its performance was evaluated based on animal experiments. The HR acquisition mode improved the spatial resolution and delineation of the fine structures in the canine's nasal turbinates compared to the standard mode. Clinical applications that rely on high-spatial resolution expectedly will also benefit from this resolution-enhancing function. The results demonstrate the potential impact on the brain tissue segmentation, improved detection of the liver tumors, and capacity to reconstruct high-resolution images both preclinically and clinically.

Indexed as

Disease Models, AnimalPhantoms, ImagingPhotonsAnimalsBrainCarcinoma, HepatocellularContrast MediaDogsFeasibility StudiesLiver NeoplasmsMaleNeural Networks, ComputerRabbitsTomography, X-Ray ComputedContrast Media

Identifiers

PMID34815501
PMCPMC8611013
OpenAlexW3217556085

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked