Evidence map›Paper›PMID 34815432›Full record

ArticleScientific reports2021

Effect of initial switch-on within 24 hours of cochlear implantation using slim modiolar electrodes.

Woongsang Sunwoo, Hyoung Won Jeon, Byung Yoon Choi

Abstract read
In one paragraph

Article in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Electrode impedance in cochlear implantation: determinants, dynamics, and clinical implications.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2026
    Review
  2. Article
  3. Effect of early activation and perimodiolar electrodes on cochlear implant impedance.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2026
    Article
  4. Article
  5. Early fitting in cochlear implant surgery: preliminary results.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2024
    Article
  6. Review
  7. Article
  8. Very early activation of cochlear implants: A review of the literature.Journal of the Chinese Medical Association : JCMA · 2023
    Review
  9. Precision Medicine Approach to Cochlear Implantation.Clinical and experimental otorhinolaryngology · 2022
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Woongsang Sunwoo *Department of Otorhinolaryngology-Head and Neck Surgery, Gil Medical Center, Gachon University College of Medicine, Incheon, Republic of Korea.
Hyoung Won Jeon *Department of Otorhinolaryngology-Head and Neck Surgery, Seoul National University Bundang Hospital, Seoul National University College of Medicine, 300 Gumi-dong, Bundang-gu, Seongnam, 13620, Republic of Korea.
Byung Yoon ChoiDepartment of Otorhinolaryngology-Head and Neck Surgery, Seoul National University Bundang Hospital, Seoul National University College of Medicine, 300 Gumi-dong, Bundang-gu, Seongnam, 13620, Republic of Korea. choiby@snubh.org.

Funding

Gil Medical Center, Gachon University FRD2019-01-02SNUBH Research Fund 00-2020-13-2018-015, 00-2020-13-2016-014, 00-2020-13-2015-019, 02-2017-060 and, 18-2018-009The Korea Medical Device Development Fund grant KMDF-PR-20200901-0147The national research foundation of Korea 2020R1C1C100548812
6 · The paper itself

Abstract

Reducing electrode impedance is an important factor in improving the functional benefits of cochlear implants (CIs). The immediate effect of early switch-on within 24 h of surgery on impedance among CI recipients with various types of electrodes has been reported previously; however, the immediate change and the evolution of electrode impedances of slim modiolar electrodes after early switch-on within 24 h of implantation has not. Therefore, the focus of this retrospective cohort study of CI patients was to compare the effect of early switch-on (n = 36) and conventional switch-on (n = 72) 2-4 weeks post-operation on impedance. Compared with impedance measured intraoperatively, our results demonstrate a significant decrease in impedance from 11.5 to 8.9 kΩ (p < 0.001) at 2-4 weeks after implantation in the early switch-on group, which sharply contrasted with elevated impedance values for conventional switch-on 2-4 weeks after implantation (from 10.7 to 14.2 kΩ, p = 0.001). Notably, a comparatively lower impedance than the conventional switch-on protocol was observed for up to 2 months post-operation. Most importantly, a much earlier stabilization of impedance can be achieved with the early switch-on protocol coupled with the slim modiolar electrode array compared to the conventional switch-on protocol, offering the advantage of reducing the number of required mapping sessions in the early stages of rehabilitation.

Indexed as

Electric ImpedanceElectrodes, ImplantedCochleaCochlear ImplantationCochlear ImplantsHumansLongitudinal StudiesRetrospective Studies

Identifiers

PMID34815432
PMCPMC8611070

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.