Evidence map›Paper›PMID 34814887›Full record

ArticleBMC musculoskeletal disorders2021

Applicable safety analysis and biomechanical study of iliosacral triangular osteosynthesis.

Jianxiong Zheng, Jie Xiang, Xiaoreng Feng, Fei Liu, Keyu Chen, Bin Chen

Open access · goldAbstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.2field-weighted citation impact, top 43% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 5 citations in OpenAlex.

  1. Percutaneous fixation of posterior pelvic ring lesions in the elderly: current evidence and recent advances.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2026
    Review
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Jianxiong Zheng *Division of Orthopaedics and Traumatology, Department of Orthopaedics, Nanfang Hospital, Southern Medical University, No. 1838 North Guangzhou Avenue, Guangzhou, 510515, China.
Jie Xiang *Division of Orthopaedics and Traumatology, Department of Orthopaedics, Nanfang Hospital, Southern Medical University, No. 1838 North Guangzhou Avenue, Guangzhou, 510515, China.
Xiaoreng FengDivision of Orthopaedics and Traumatology, Department of Orthopaedics, Nanfang Hospital, Southern Medical University, No. 1838 North Guangzhou Avenue, Guangzhou, 510515, China.
Fei LiuDivision of Orthopaedics and Traumatology, Department of Orthopaedics, Nanfang Hospital, Southern Medical University, No. 1838 North Guangzhou Avenue, Guangzhou, 510515, China.
Keyu ChenDivision of Orthopaedics and Traumatology, Department of Orthopaedics, Nanfang Hospital, Southern Medical University, No. 1838 North Guangzhou Avenue, Guangzhou, 510515, China.
Bin ChenDivision of Orthopaedics and Traumatology, Department of Orthopaedics, Nanfang Hospital, Southern Medical University, No. 1838 North Guangzhou Avenue, Guangzhou, 510515, China. chb@smu.edu.cn.
Southern Medical University · CNNanfang Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe aim of this study was to investigate the applicable safety and biomechanical stability of iliosacral triangular osteosynthesis (ITO) through 3D modeling and finite element (FE) analysis.

methodsPelvic CT imaging data from 100 cases were imported into Mimics software for the construction of 3D pelvic models. The S2-alar-iliac (S2AI) screws and S2 sacroiliac screws were placed in the S2 segment with optimal distribution and their compatibility rate on the S2 safe channel was observed and analyzed. In the FE model, the posterior pelvic ring was fixed with two transsacral screws (TTS), triangular osteosynthesis (TO) and ITO, respectively. Four different loading methods were implemented in sequence to simulate the force in standing, flexion, right bending, and left twisting, respectively. The relative displacement and change in relative displacement of the three fixing methods were recorded and analyzed.

resultsThe theoretical compatibility rate of S2AI screw and S2 sacroiliac screw in S2 segment was 94%, of which 100% were in males and 88% in females. In the FE model, in terms of overall relative displacement, TTS group showed the smallest relative displacement, the ITO group showed the second smallest, and the TO group the largest relative displacement. The change in relative displacement of the TTS group displayed the smaller fluctuations in motion. The change in relative displacement of the TO group under right bending and left twisting displayed larger fluctuations, while the ITO group under flexion displayed larger fluctuations.

conclusionsThe simultaneous placement of S2AI screw and S2 sacroiliac screw in the S2 segment is theoretically safe. Although the biomechanical stability of ITO is slightly lower than TTS, it is better than TO, and can be used as a new method for the treatment of posterior pelvic ring injuries.

Indexed as

Fracture Fixation, InternalSacrumBiomechanical PhenomenaBone ScrewsFemaleHumansIliumMaleBiomechanicsIliosacral fixationS2-alar-iliac screwSacral fractureTriangular osteosynthesis

Identifiers

PMID34814887
PMCPMC8609831
OpenAlexW3215312896

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.