ArticleSe pu = Chinese journal of chromatography2021
[Determination of three urinary catecholamines and serotonin by on-line packed-fiber solid-phase extraction].
Article in Se pu = Chinese journal of chromatography, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 2 citations in OpenAlex.
- Construction and application of magnetic surface molecularly imprinted solid-phase extraction for the detection of 5-hydroxytryptamine in peripheral blood.Mikrochimica acta · 2025Article
- [Determination of catecholamines in urine by disperse solid-phase extraction-liquid chromatography based on TiSe pu = Chinese journal of chromatography · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Biogenic monoamines, including catecholamines (CAs) and serotonin (5-HT), play critical roles in the central nervous system. They have recently been proven to be primarily useful as biomarkers for the diagnosis of CA-producing tumors. The highly polar properties of biogenic monoamines result in poor retention on conventional materials, making it challenging to simultaneously measure more biogenic monoamines from complex matrices. Moreover, the classical method of off-line pretreatment is relatively complex, labor-intensive, and incurs errors in repeatability among different operators. Therefore, the development of an on-line sample pretreatment method combined with the use of specific nanofiber adsorbents has been explored. An on-line procedure could avoid unnecessary and time-consuming steps, and enable full automation of the experimental process. In this study, an on-line packed-fiber solid-phase extraction (PFSPE) and determination method for urinary CAs (dopamine (DA), norepinephrine (NE), epinephrine (E)) and 5-HT was developed, using composite nanofibers of polycrown ether-polystyrene (PCE-PS). PCE-PS composite nanofibers prepared by electrospinning were used as adsorbents in the PFSPE column, which was connected to the on-line HPLC system. The PFSPE-HPLC equipment contained a dual ternary pump and a switching valve to enable enrichment, purification, and analysis directly in the system. The left pump was connected with the PFSPE column for sample enrichment and purification, while the right pump was attached to the analysis column for sample separation and testing. The switching valve was controlled such that after enrichment, the samples could be eluted to the analysis column for separation and detection. The current work expands on our previous research by analyzing more target substances, and developing an on-line sample pretreatment method to simultaneously analyze four biogenic monoamines. Gradient separation aided in the satisfactory separation of the biogenic monoamines within a short retention time. The running time was set at 16 min to enable thorough enrichment, elution, and analysis. The influence of the complexing reagent (diphenylborinic acid 2-aminoethyl ester, 2 mg/mL) was also investigated with this on-line PFSPE-HPLC system. The results showed that the intensity of most analytes was significantly higher when 50 μL of the complexing reagent was added. The influence of a buffer on the extraction of the biogenic monoamines was also tested. The optimum extraction condition for the target analytes was achieved when artificial urine (AU) samples were diluted in a volume ratio of 1∶1 by phosphate- buffered saline solution (PBS, pH 7.8). Under the optimum experimental conditions, the on-line PFSPE-HPLC procedure showed good linearity (in the range of 1 ng/mL to 200 ng/mL) with correlation coefficients above 0.996 for the quantitative detection of urinary CAs (DA, NE, E) and 5-HT. For the CAs, the limit of detection (LOD) was 1 ng/mL (
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.