Evidence map›Paper›PMID 34806024›Full record

ArticlePhotoniX2021

Liquid crystal-amplified optofluidic biosensor for ultra-highly sensitive and stable protein assay.

Ziyihui Wang, Yize Liu, Chaoyang Gong, Zhiyi Yuan, Liang Shen, Pengxiang Chang, Kun Liu, Tianhua Xu, Junfeng Jiang, Yu-Cheng Chen and 1 more

Abstract read
In one paragraph

Article in PhotoniX, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Review
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Ziyihui WangSchool of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin, 300072 China.
Yize LiuSchool of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin, 300072 China.
Chaoyang GongSchool of Electrical and Electronics Engineering, Nanyang Technological University, Singapore, 639798 Singapore.
Zhiyi YuanSchool of Electrical and Electronics Engineering, Nanyang Technological University, Singapore, 639798 Singapore.
Liang ShenSchool of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin, 300072 China.
Pengxiang ChangSchool of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin, 300072 China.
Kun LiuSchool of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin, 300072 China.
Tianhua XuSchool of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin, 300072 China.
Junfeng JiangSchool of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin, 300072 China.
Yu-Cheng ChenSchool of Electrical and Electronics Engineering, Nanyang Technological University, Singapore, 639798 Singapore.
Tiegen LiuSchool of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin, 300072 China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Protein assays show great importance in medical research and disease diagnoses. Liquid crystals (LCs), as a branch of sensitive materials, offer promising applicability in the field of biosensing. Herein, we developed an ultrasensitive biosensor for the detection of low-concentration protein molecules, employing LC-amplified optofluidic resonators. In this design, the orientation of LCs was disturbed by immobilized protein molecules through the reduction of the vertical anchoring force from the alignment layer. A biosensing platform based on the whispering-gallery mode (WGM) from the LC-amplified optofluidic resonator was developed and explored, in which the spectral wavelength shift was monitored as the sensing parameter. The microbubble structure provided a stable and reliable WGM resonator with a high Q factor for LCs. It is demonstrated that the wall thickness of the microbubble played a key role in enhancing the sensitivity of the LC-amplified WGM microcavity. It is also found that protein molecules coated on the internal surface of microbubble led to their interactions with laser beams and the orientation transition of LCs. Both effects amplified the target information and triggered a sensitive wavelength shift in WGM spectra. A detection limit of 1 fM for bovine serum albumin (BSA) was achieved to demonstrate the high-sensitivity of our sensing platform in protein assays. Compared to the detection using a conventional polarized optical microscope (POM), the sensitivity was improved by seven orders of magnitude. Furthermore, multiple types of proteins and specific biosensing were also investigated to verify the potential of LC-amplified optofluidic resonators in the biomolecular detection. Our studies indicate that LC-amplified optofluidic resonators offer a new solution for the ultrasensitive real-time biosensing and the characterization of biomolecular interactions. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s43074-021-00041-1.

Indexed as

BiosensorLiquid crystalMicrofluidicProtein assayWhispering-gallery mode

Identifiers

PMID34806024
PMCPMC8397869

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.