Evidence map›Paper›PMID 34804193›Full record

ArticleComputational and mathematical methods in medicine2021

Analysis of the Dose Drop at the Edge of the Target Area in Heavy Ion Radiotherapy.

Xiaoyun Ma, Mengling Zhang, Wanbin Meng, Xiaoli Lu, Ziheng Wang, Yanshan Zhang

Abstract read
In one paragraph

Article in Computational and mathematical methods in medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Xiaoyun MaDepartment of Medical Physics, Wuwei Tumor Hospital Heavy Ion Therapy Center, No. 31 Sanitary Lane, Haizang Road, Wuwei City, Gansu Province, China 733000.ORCID https://orcid.org/0000-0002-8661-1237
Mengling ZhangDepartment of Medical Physics, Wuwei Tumor Hospital Heavy Ion Therapy Center, No. 31 Sanitary Lane, Haizang Road, Wuwei City, Gansu Province, China 733000.ORCID https://orcid.org/0000-0001-7890-0226
Wanbin MengDepartment of Medical Physics, Wuwei Tumor Hospital Heavy Ion Therapy Center, No. 31 Sanitary Lane, Haizang Road, Wuwei City, Gansu Province, China 733000.ORCID https://orcid.org/0000-0002-3738-5325
Xiaoli LuDepartment of Medical Physics, Wuwei Tumor Hospital Heavy Ion Therapy Center, No. 31 Sanitary Lane, Haizang Road, Wuwei City, Gansu Province, China 733000.ORCID https://orcid.org/0000-0002-4331-1429
Ziheng WangDepartment of Medical Physics, Wuwei Tumor Hospital Heavy Ion Therapy Center, No. 31 Sanitary Lane, Haizang Road, Wuwei City, Gansu Province, China 733000.ORCID https://orcid.org/0000-0003-3195-2250
Yanshan ZhangDepartment of Heavy Ion Radiotherapy, Wuwei Tumor Hospital, No. 31 Sanitary Lane, Haizang Road, Wuwei City, Gansu Province, China 733000.ORCID https://orcid.org/0000-0003-4621-148X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe dose distribution of heavy ions at the edge of the target region will have a steep decay during radiotherapy, which can better protect the surrounding organs at risk.

objectiveTo analyze the dose decay gradient at the back edge of the target region during heavy ion radiotherapy.

methodsTreatment planning system (TPS) was employed to analyze the dose decay at the edge of the beam under different incident modes and multiple dose segmentation conditions during fixed beam irradiation. The dose decay data of each plan was collected based on the position where the rear edge of the beam began to fall rapidly. Uniform scanning mode was selected in heavy ion TPS. Dose decay curves under different beam setup modes were drawn and compared.

resultsThe dose decay data analysis showed that in the case of single beam irradiation, the posterior edge of the beam was 5 mm away, and the posterior dose could drop to about 20%. While irradiation in opposite direction, the posterior edge of the beam was 5 mm away, and the dose could drop to about 50%. In orthogonal irradiation of two beams, the posterior edge of the beam could drop to about 30-38% in a distance of 5 mm. Through the data analysis in the TPS, the sharpness of the dose at the back edge of the heavy ion beam is better than that at the lateral edge, but the generated X-ray contamination cannot be ignored.

conclusionsThe effect of uneven CT value on the dose decay of heavy ion beam should also be considered in clinical treatment.

Indexed as

Computational BiologyDose Fractionation, RadiationHeavy Ion RadiotherapyHumansNeoplasmsPhantoms, ImagingRadiotherapy DosageRadiotherapy Planning, Computer-AssistedReference StandardsTomography, X-Ray Computed

Identifiers

PMID34804193
PMCPMC8601813

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.