Trial reportBMC cardiovascular disorders2021

Diagnostic performance of a wearing dynamic ECG recorder for atrial fibrillation screening: the HUAMI heart study.

Wenxia Fu, Ruogu Li

Open access · goldAbstract readClinical Trial
In one paragraph

Trial report in BMC cardiovascular disorders, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed, 1 pooled it
1.7field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 1 synthesis or guideline pooled it, 20 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Article
  4. Review
  5. Artificial intelligence-powered advancements in atrial fibrillation diagnostics: a systematic review.The Egyptian heart journal : (EHJ) : official bulletin of the Egyptian Society of Cardiology · 2025
    Review
  6. Review
  7. Article
  8. Review
  9. Review
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Wenxia FuDepartment of Cardiac Function, Shanghai Chest Hospital, Shanghai Jiao Tong University, 241 Huaihai West Rd, Xuhui District, 200030, Shanghai, China.
Ruogu LiDepartment of Cardiac Function, Shanghai Chest Hospital, Shanghai Jiao Tong University, 241 Huaihai West Rd, Xuhui District, 200030, Shanghai, China. liruogu1234@163.com.ORCID 0000-0002-4456-919X
Shanghai Jiao Tong University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAtrial fibrillation (AF) is the most prevalent cardiac dysrhythmia with high morbidity and mortality rate. Evidence shows that in every three patients with AF, one is asymptomatic. The asymptomatic and paroxysmal nature of AF is the reason for unsatisfactory and delayed detection using traditional instruments. Research indicates that wearing a dynamic electrocardiogram (ECG) recorder can guide accurate and safe analysis, interpretation, and distinction of AF from normal sinus rhythm. This is also achievable in an upright position and after exercises, assisted by an artificial intelligence (AI) algorithm.

methodsThis study enrolled 114 participants from the outpatient registry of our institution from June 24, 2020 to July 24, 2020. Participants were tested with a wearable dynamic ECG recorder and 12-lead ECG in a supine, an upright position and after exercises for 60 s.

resultsOf the 114 subjects enrolled in the study, 61 had normal sinus rhythm and 53 had AF. The number of cases that could not be determined by the wristband of dynamic ECG recorder was two, one and one respectively. Case results that were not clinically objective were defined as false-negative or false-positive. Results for diagnostic accuracy, sensitivity, and specificity tested by wearable dynamic ECG recorders in a supine position were 94.74% (95% CI% 88.76-97.80%), 88.68% (95% CI 77.06-95.07%), and 100% (95% CI 92.91-100%), respectively. Meanwhile, the diagnostic accuracy, sensitivity and specificity in an upright position were 97.37% (95% CI 92.21-99.44%), 94.34% (95% CI 84.03-98.65%), and 100% (95% CI 92.91-100%), respectively. Similar results as those of the upright position were obtained after exercise.

conclusionThe widely accessible wearable dynamic ECG recorder integrated with an AI algorithm can efficiently detect AF in different postures and after exercises. As such, this tool holds great promise as a useful and user-friendly screening method for timely AF diagnosis in at-risk individuals.

Indexed as

Action PotentialsHeart RateWearable Electronic DevicesAdultAgedAged, 80 and overArtificial IntelligenceAtrial FibrillationChinaElectrocardiographyEquipment DesignExercise TestFemaleHumansMaleMiddle AgedAccuracyAtrial fibrillationDetectionDynamic ECG recorderOne-lead ECG

Identifiers

PMID34800984
PMCPMC8606080
OpenAlexW3176176315

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.