Evidence map›Paper›PMID 34796707›Full record

ArticleJournal of biomedical optics2021

Polydimethylsiloxane tissue-mimicking phantoms with tunable optical properties.

Aaron M Goldfain, Paul Lemaillet, David W Allen, Kimberly A Briggman, Jeeseong Hwang

Abstract read
In one paragraph

Article in Journal of biomedical optics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 28 papers.

0numbers the graph read from it
0cells of the map it votes in
28citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

28 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Aaron M GoldfainNational Institute of Standards and Technology, Sensor Science Division, Gaithersburg, Maryland, United States.
Paul LemailletNational Institute of Standards and Technology, Sensor Science Division, Gaithersburg, Maryland, United States.
David W AllenNational Institute of Standards and Technology, Sensor Science Division, Gaithersburg, Maryland, United States.
Kimberly A BriggmanNational Institute of Standards and Technology, Applied Physics Division, Boulder, Colorado, United States.
Jeeseong HwangNational Institute of Standards and Technology, Applied Physics Division, Boulder, Colorado, United States.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

significanceThe polymer, polydimethylsiloxane (PDMS), has been increasingly used to make tissue simulating phantoms due to its excellent processability, durability, flexibility, and limited tunability of optical, mechanical, and thermal properties. We report on a robust technique to fabricate PDMS-based tissue-mimicking phantoms where the broad range of scattering and absorption properties are independently adjustable in the visible- to near-infrared wavelength range from 500 to 850 nm. We also report on an analysis method to concisely quantify the phantoms' broadband characteristics with four parameters.

aimWe report on techniques to manufacture and characterize solid tissue-mimicking phantoms of PDMS polymers. Tunability of the absorption (μa  (  λ  )  ) and reduced scattering coefficient spectra (μs'(λ)) in the wavelength range of 500 to 850 nm is demonstrated by adjusting the concentrations of light absorbing carbon black powder (CBP) and light scattering titanium dioxide powder (TDP) added into the PDMS base material. APPROACH: The μa  (  λ  )   and μs'(λ) of the phantoms were obtained through measurements with a broadband integrating sphere system and by applying an inverse adding doubling algorithm. Analyses of μa  (  λ  )   and μs'(λ) of the phantoms, by fitting them to linear and power law functions, respectively, demonstrate that independent control of μa  (  λ  )   and μs'(λ) is possible by systematically varying the concentrations of CBP and TDP.

resultsOur technique quantifies the phantoms with four simple fitting parameters enabling a concise tabulation of their broadband optical properties as well as comparisons to the optical properties of biological tissues. We demonstrate that, to a limited extent, the scattering properties of our phantoms mimic those of human tissues of various types. A possible way to overcome this limitation is demonstrated with phantoms that incorporate polystyrene microbead scatterers.

conclusionsOur manufacturing and analysis techniques may further promote the application of PDMS-based tissue-mimicking phantoms and may enable robust quality control and quality checks of the phantoms.

Indexed as

DimethylpolysiloxanesHumansPhantoms, ImagingDimethylpolysiloxanesabsorption coefficient spectrumintegrating spherepolydimethylsiloxanescattering coefficient spectrumtissue-mimicking phantom

Identifiers

PMID34796707
PMCPMC8601433

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.